The Yamasaki TT1315 Fibre Optic Talk Set provides hands-free, full-duplex voice communication over a spare singlemode fibre. Supplied as a two-unit pack with headsets, protective boots and carry cases, it helps technicians coordinate installation and maintenance work between fibre endpoints. Additionally, FC/PC connections and battery operation support practical field use.
| File | File size |
|---|---|
| Yamasaki TT1315 Fibre Optic Talk Set | 1,011 KB |
The Yamasaki TT1315 Fibre Optic Talk Set provides hands-free voice communication between technicians over a spare singlemode fibre. With full-duplex digital audio, both users can speak and listen simultaneously. To discuss your connection requirements, request a Rapid Quote from Anderson Corporation.
The TT1315 comes as a two-unit pack with headsets, protective boots and carry cases. Additionally, its automatic call detection and straightforward menu system support practical operation during installation and maintenance work.
Fibre installation often places technicians in separate locations. For example, one person may work at a communications rack while another prepares connections at a remote cabinet.
A fibre optic talk set provides a voice connection through a suitable spare fibre between those locations. Consequently, technicians can discuss the next step without repeatedly moving between endpoints.
This arrangement can help teams coordinate activities such as:
However, the communication fibre must remain connected while the conversation takes place. Therefore, plan which fibre will carry the talk-set connection before starting work.
The TT1315 supports full-duplex digital audio. This means both technicians can speak and hear each other at the same time.
For example, the remote technician can ask a question while the local technician explains a connection change. Consequently, neither person needs to wait for a push-to-talk exchange.
The supplied headsets also support hands-free conversation. As a result, technicians can keep their hands available for suitable installation and testing tasks while maintaining contact.
Additionally, the flip-out stand allows each unit to sit beside the work area. This gives users a practical arrangement when working at a bench, rack or cabinet.
The Yamasaki TT1315 uses a spare singlemode fibre as its communication path. Therefore, it suits work where technicians have access to a continuous, available fibre between their locations.
Before selecting the equipment, establish the following:
| Selection point | What to confirm |
|---|---|
| Fibre type | A suitable singlemode fibre connects the two locations |
| Fibre availability | The selected fibre is spare and available for the task |
| Route continuity | Patching and splicing provide a continuous optical path |
| Connector arrangement | Suitable leads connect the route to the TT1315 FC/PC interfaces |
| Link loss | Total optical loss suits the equipment’s operating capability |
| Endpoint access | Technicians can access and connect equipment at both ends |
| Power requirements | Suitable batteries or the specified external supply are available |
Additionally, check whether other teams expect to use the same spare fibre during your work. Clear allocation helps prevent an unexpected disconnection.
If your work involves repeatedly disconnecting the fibre under test, consider allocating another spare fibre to the talk sets.
For example, one fibre can maintain the conversation while technicians test other fibres in the cable. Consequently, the team can discuss results and coordinate connection changes without interrupting its voice path.
However, this arrangement depends on spare fibre availability. Therefore, include the proposed communication path in your job preparation.
The TT1315 datasheet lists a transmission distance of at least 100 km and a dynamic range of at least 33 dB. However, these specifications do not guarantee operation across every installed route of that length.
Actual suitability depends on the complete optical path. For example, connector losses, splice losses, fibre attenuation and other components all affect the signal reaching the remote unit.
Therefore, consider both route length and total loss when planning the connection.
A shorter route with poor connections may present difficulties. Conversely, a well-maintained route can provide a more suitable optical path.
Before ordering for a demanding application, provide Anderson Corporation with the available route details. Additionally, include any existing loss measurements and information about intermediate components.
A successful voice connection requires a suitable path between both talk-set units. Therefore, verify the intended route before beginning work that depends on continuous communication.
First, confirm the fibre identification at each endpoint. Next, check the patching arrangement and prepare the required connection leads.
Then, establish a call and confirm that both technicians can hear each other clearly. Finally, agree on how you will reconnect if the optical path changes during the job.
This preparation helps identify connection problems while both technicians can still resolve them efficiently.
The TT1315 combines its optical voice connection with features that support everyday use.
| Feature | Practical purpose |
|---|---|
| Full-duplex digital audio | Allows simultaneous speaking and listening |
| Hands-free headsets | Keeps hands available during suitable work tasks |
| Automatic call detection | Helps users recognise an incoming call |
| Simple menu system | Supports straightforward operation |
| Selectable backlight | Allows users to adjust display illumination |
| Flip-out stand | Supports placement beside the work area |
| Removable protective boots | Adds protection around the instruments |
| Optical connector protection caps | Covers optical interfaces between uses |
| Carry cases | Provides storage and transport for the equipment |
Additionally, the datasheet lists a 2 kHz source tone and 2 kHz tone detection. If tone operation forms part of your intended workflow, confirm the required configuration before ordering.
The following specifications come from the published TT1315 datasheet.
| Specification | Published value |
|---|---|
| Model | Yamasaki TT1315 |
| Wavelengths | 1310/1550 nm |
| Emitter type | FP-LD |
| Transmission distance | ≥100 km |
| Dynamic range | ≥33 dB |
| Optical connector | FC/PC |
| Listed modulation settings | CW, 270 Hz, 1 kHz and 2 kHz |
| Output stability | ≤0.1 dB over 30 minutes at 20°C |
| Power supply | Three 1.5 V alkaline batteries or an 8.4 V power supply adaptor |
| Battery operating time | 5 hours |
| Operating temperature | −10°C to +60°C |
| Storage temperature | −25°C to +70°C |
| Dimensions | 198 × 102 × 50 mm |
| Listed weight | 310 g |
Battery endurance will vary with operating conditions and battery condition. Additionally, confirm current specifications and supplied accessories when requesting your quote.
For the manufacturer’s published information, download the Yamasaki TT1315 Fibre Optic Talk Set datasheet.
The TT1315 datasheet specifies FC/PC optical connections. Therefore, select connection leads that suit both the instrument and your installed fibre interface.
For example, a route terminating at an SC or LC patch panel will require a suitable connection arrangement between that panel and the talk set.
Additionally, connector polish matters. Match each mating interface correctly, and avoid directly mating APC and PC connectors.
Before requesting a quote, identify:
This information helps define the accessories your team needs. Consequently, you can prepare a complete setup before attending the site.
Contamination at an optical interface can increase loss and interfere with the connection. Therefore, inspect and clean the relevant connectors before use.
Additionally, protect disconnected leads and instrument ports while preparing the setup. Refit protective caps when storing the equipment.
If communication becomes intermittent, check the connection arrangement and connector condition as part of your investigation. However, avoid assuming that every problem comes from the instrument itself.
A talk set can support coordination when technicians need to complete related tasks at opposite ends of a route.
For example, one technician may prepare a panel connection while the other checks the corresponding remote position. A direct conversation allows each person to confirm the identification before proceeding.
Similarly, technicians can agree on the sequence for changing test leads or moving to another fibre. Consequently, the team can reduce uncertainty about what happens next.
Before beginning, establish a simple working sequence:
If the job requires changes to that path, agree on the next contact method before disconnecting it.
Maintenance work often requires technicians to compare observations from different locations. Therefore, a dedicated optical voice path can help them coordinate the investigation.
For example, one technician can describe the remote patching arrangement while the other checks the local panel. Additionally, both users can confirm when equipment is ready for the next measurement.
The talk set provides communication during this process. Separate test instruments provide the measurements needed to assess the fibre link.
Consequently, plan your communication equipment alongside the testing equipment required for the job.
The published datasheet describes the TT1315 as a two-unit pack and lists:
Therefore, the package provides a talk-set unit for each end of the communication path.
Additionally, confirm the supply of batteries, power adaptors and connection leads when ordering. This helps ensure your quotation covers the equipment and accessories required for your application.
Choosing the right Fibre Optic Talk Set involves understanding your communication requirements, available fibre path and connection arrangement. Therefore, this Knowledge Centre will bring together practical guidance to help you select and use talk sets effectively.
As the Knowledge Centre grows, we will add published articles under the categories below. These resources will support technicians, contractors and network operators planning communication between fibre endpoints.
Our educational guides will explain how fibre optic talk sets work and when to use them.
Additionally, they will cover spare-fibre communication, full-duplex audio and the role of talk sets during installation and maintenance.
Reliable communication starts with a suitable optical path. Therefore, our technical guides will explore singlemode fibre requirements, operating wavelengths, optical loss and communication distance.
They will also explain connector compatibility and the factors that influence talk-set performance.
Different projects require different communication arrangements. Accordingly, our comparison guides will examine fibre optic talk sets alongside other communication options.
These articles will help you assess each approach against your site access, available infrastructure and working requirements.
Before ordering a fibre optic talk set, confirm the equipment and accessories your team needs.
Our procurement and specification guides will cover connection leads, optical interfaces, power arrangements and package contents. Consequently, you can prepare a clearer enquiry and select a complete working setup.
Correct preparation helps technicians establish communication efficiently. Therefore, our setup and operation guides will cover fibre allocation, connection preparation, headset use and initial communication checks.
Additionally, they will explain how to maintain a dedicated voice path while working on other fibres.
Communication difficulties can arise from several parts of the optical path. For this reason, our problem-solving guides will explore connection issues, excessive optical loss, interrupted fibre routes and power-related checks.
These articles will provide a structured approach to investigating unsuccessful or intermittent communication.
Looking after your talk sets helps keep them ready for the next job. Accordingly, these guides will cover connector care, equipment inspection, battery management, transport and storage.
Additionally, they will explain practical checks before deploying equipment to site.
Communication requirements vary between projects and working environments. Therefore, our application guides will explore talk-set use during telecommunications installation, campus network projects and fibre maintenance.
Each article will focus on planning communication around a suitable spare fibre and the tasks technicians need to coordinate.
For more fibre optic product information, visit the Anderson Corporation YouTube Channel.
A fibre optic talk set carries voice communication over a suitable optical fibre between two locations. Therefore, technicians can talk while working at opposite ends of the route.
The Yamasaki TT1315 uses a spare singlemode fibre for this purpose.
Yes. The TT1315 supports full-duplex digital audio, allowing both users to speak and listen simultaneously.
Additionally, the supplied headsets support hands-free operation.
The talk-set voice connection travels through the optical fibre between the units. Therefore, that connection does not depend on mobile phone coverage.
However, both units still require power and a suitable continuous optical path.
The published product information specifies spare singlemode fibre. Therefore, select the TT1315 for that stated application and discuss other fibre types with Anderson Corporation before ordering.
The published information describes operation over a spare singlemode fibre. Therefore, plan a dedicated available fibre rather than assuming compatibility with a live service.
If your proposed route includes active equipment or other optical signals, discuss the arrangement before connecting the talk sets.
No. Although the datasheet lists a transmission distance of at least 100 km, actual suitability depends on the optical path and its total loss.
Therefore, provide route length, connection details and available loss measurements when seeking advice.
The datasheet specifies FC/PC. Consequently, you will need suitable leads to connect the instruments to your installed fibre interfaces.
Additionally, confirm connector polish at each mating connection.
The datasheet lists five hours of battery operation. However, actual endurance depends on battery condition and operating conditions.
For longer tasks, plan the power arrangement before attending the site.
Use a suitable optical light source and power meter when you need insertion loss measurements. The TT1315’s principal role is voice communication between technicians.
Similarly, use an OTDR when you need trace-based information about events along a fibre route.
Yes. The TT1315 comes as a two-unit pack, with two headsets, two protective boots and two carry cases listed in the datasheet.
Additionally, confirm any required connection leads and power accessories when requesting your quotation.
The Yamasaki TT1315 Fibre Optic Talk Set helps technicians maintain voice contact over a spare singlemode fibre. Additionally, its full-duplex audio and hands-free headsets support coordination while working at separate endpoints.
To prepare your enquiry, include the route length, fibre availability and connector details. If available, also provide the measured link loss and your preferred power arrangement.
Request a Rapid Quote from Anderson Corporation for the TT1315 and the accessories required for your application.
| File | File size |
|---|---|
| Yamasaki TT1315 Fibre Optic Talk Set | 1,011 KB |