Fibre Optic Talk Set

The Yamasaki TT1315 Fibre Optic Talk Set provides hands-free, full-duplex voice communication over a spare singlemode fibre. Supplied as a two-unit pack with headsets, protective boots and carry cases, it helps technicians coordinate installation and maintenance work between fibre endpoints. Additionally, FC/PC connections and battery operation support practical field use.

SKU: TT1315

Attachments

File File size
Yamasaki TT1315 Fibre Optic Talk Set 1,011 KB

Fibre Optic Talk Set

The Yamasaki TT1315 Fibre Optic Talk Set provides hands-free voice communication between technicians over a spare singlemode fibre. With full-duplex digital audio, both users can speak and listen simultaneously. To discuss your connection requirements, request a Rapid Quote from Anderson Corporation.

The TT1315 comes as a two-unit pack with headsets, protective boots and carry cases. Additionally, its automatic call detection and straightforward menu system support practical operation during installation and maintenance work.

Communication Between Both Ends of a Fibre Link

Fibre installation often places technicians in separate locations. For example, one person may work at a communications rack while another prepares connections at a remote cabinet.

A fibre optic talk set provides a voice connection through a suitable spare fibre between those locations. Consequently, technicians can discuss the next step without repeatedly moving between endpoints.

This arrangement can help teams coordinate activities such as:

  • Confirming rack, panel and port identification.
  • Preparing for a change in test direction.
  • Checking when the remote technician is ready.
  • Coordinating patching and connection changes.
  • Discussing observations during fault investigation.
  • Confirming completion before disconnecting equipment.

However, the communication fibre must remain connected while the conversation takes place. Therefore, plan which fibre will carry the talk-set connection before starting work.

Full-Duplex Fibre Optic Talk Set Communication

The TT1315 supports full-duplex digital audio. This means both technicians can speak and hear each other at the same time.

For example, the remote technician can ask a question while the local technician explains a connection change. Consequently, neither person needs to wait for a push-to-talk exchange.

The supplied headsets also support hands-free conversation. As a result, technicians can keep their hands available for suitable installation and testing tasks while maintaining contact.

Additionally, the flip-out stand allows each unit to sit beside the work area. This gives users a practical arrangement when working at a bench, rack or cabinet.

A Fibre Optic Talk Set for Spare Singlemode Fibre

The Yamasaki TT1315 uses a spare singlemode fibre as its communication path. Therefore, it suits work where technicians have access to a continuous, available fibre between their locations.

Before selecting the equipment, establish the following:

Selection point What to confirm
Fibre type A suitable singlemode fibre connects the two locations
Fibre availability The selected fibre is spare and available for the task
Route continuity Patching and splicing provide a continuous optical path
Connector arrangement Suitable leads connect the route to the TT1315 FC/PC interfaces
Link loss Total optical loss suits the equipment’s operating capability
Endpoint access Technicians can access and connect equipment at both ends
Power requirements Suitable batteries or the specified external supply are available

Additionally, check whether other teams expect to use the same spare fibre during your work. Clear allocation helps prevent an unexpected disconnection.

Plan a Separate Communication Fibre During Testing

If your work involves repeatedly disconnecting the fibre under test, consider allocating another spare fibre to the talk sets.

For example, one fibre can maintain the conversation while technicians test other fibres in the cable. Consequently, the team can discuss results and coordinate connection changes without interrupting its voice path.

However, this arrangement depends on spare fibre availability. Therefore, include the proposed communication path in your job preparation.

Long-Distance Communication and Optical Loss

The TT1315 datasheet lists a transmission distance of at least 100 km and a dynamic range of at least 33 dB. However, these specifications do not guarantee operation across every installed route of that length.

Actual suitability depends on the complete optical path. For example, connector losses, splice losses, fibre attenuation and other components all affect the signal reaching the remote unit.

Therefore, consider both route length and total loss when planning the connection.

A shorter route with poor connections may present difficulties. Conversely, a well-maintained route can provide a more suitable optical path.

Before ordering for a demanding application, provide Anderson Corporation with the available route details. Additionally, include any existing loss measurements and information about intermediate components.

Check the Route Before Relying on the Connection

A successful voice connection requires a suitable path between both talk-set units. Therefore, verify the intended route before beginning work that depends on continuous communication.

First, confirm the fibre identification at each endpoint. Next, check the patching arrangement and prepare the required connection leads.

Then, establish a call and confirm that both technicians can hear each other clearly. Finally, agree on how you will reconnect if the optical path changes during the job.

This preparation helps identify connection problems while both technicians can still resolve them efficiently.

Practical Features for Field Work

The TT1315 combines its optical voice connection with features that support everyday use.

Feature Practical purpose
Full-duplex digital audio Allows simultaneous speaking and listening
Hands-free headsets Keeps hands available during suitable work tasks
Automatic call detection Helps users recognise an incoming call
Simple menu system Supports straightforward operation
Selectable backlight Allows users to adjust display illumination
Flip-out stand Supports placement beside the work area
Removable protective boots Adds protection around the instruments
Optical connector protection caps Covers optical interfaces between uses
Carry cases Provides storage and transport for the equipment

Additionally, the datasheet lists a 2 kHz source tone and 2 kHz tone detection. If tone operation forms part of your intended workflow, confirm the required configuration before ordering.

Yamasaki TT1315 Technical Specifications

The following specifications come from the published TT1315 datasheet.

Specification Published value
Model Yamasaki TT1315
Wavelengths 1310/1550 nm
Emitter type FP-LD
Transmission distance ≥100 km
Dynamic range ≥33 dB
Optical connector FC/PC
Listed modulation settings CW, 270 Hz, 1 kHz and 2 kHz
Output stability ≤0.1 dB over 30 minutes at 20°C
Power supply Three 1.5 V alkaline batteries or an 8.4 V power supply adaptor
Battery operating time 5 hours
Operating temperature −10°C to +60°C
Storage temperature −25°C to +70°C
Dimensions 198 × 102 × 50 mm
Listed weight 310 g

Battery endurance will vary with operating conditions and battery condition. Additionally, confirm current specifications and supplied accessories when requesting your quote.

For the manufacturer’s published information, download the Yamasaki TT1315 Fibre Optic Talk Set datasheet.

Connecting Your Fibre Optic Talk Set

The TT1315 datasheet specifies FC/PC optical connections. Therefore, select connection leads that suit both the instrument and your installed fibre interface.

For example, a route terminating at an SC or LC patch panel will require a suitable connection arrangement between that panel and the talk set.

Additionally, connector polish matters. Match each mating interface correctly, and avoid directly mating APC and PC connectors.

Before requesting a quote, identify:

  • The connector type at each endpoint.
  • The connector polish at each mating interface.
  • The required lead lengths.
  • Any intermediate patch panels or adaptors.
  • Whether suitable connection leads already form part of your equipment kit.

This information helps define the accessories your team needs. Consequently, you can prepare a complete setup before attending the site.

Prepare Clean Optical Connections

Contamination at an optical interface can increase loss and interfere with the connection. Therefore, inspect and clean the relevant connectors before use.

Additionally, protect disconnected leads and instrument ports while preparing the setup. Refit protective caps when storing the equipment.

If communication becomes intermittent, check the connection arrangement and connector condition as part of your investigation. However, avoid assuming that every problem comes from the instrument itself.

Using a Fibre Optic Talk Set During Installation

A talk set can support coordination when technicians need to complete related tasks at opposite ends of a route.

For example, one technician may prepare a panel connection while the other checks the corresponding remote position. A direct conversation allows each person to confirm the identification before proceeding.

Similarly, technicians can agree on the sequence for changing test leads or moving to another fibre. Consequently, the team can reduce uncertainty about what happens next.

Before beginning, establish a simple working sequence:

  1. First, confirm the allocated communication fibre.
  2. Next, connect the talk-set units using suitable leads.
  3. Then, establish the voice connection.
  4. Confirm the endpoint and fibre identification verbally.
  5. Agree on the planned work sequence.
  6. Finally, maintain the communication path while completing the relevant tasks.

If the job requires changes to that path, agree on the next contact method before disconnecting it.

Using a Fibre Optic Talk Set During Maintenance

Maintenance work often requires technicians to compare observations from different locations. Therefore, a dedicated optical voice path can help them coordinate the investigation.

For example, one technician can describe the remote patching arrangement while the other checks the local panel. Additionally, both users can confirm when equipment is ready for the next measurement.

The talk set provides communication during this process. Separate test instruments provide the measurements needed to assess the fibre link.

Consequently, plan your communication equipment alongside the testing equipment required for the job.

What Comes with the TT1315?

The published datasheet describes the TT1315 as a two-unit pack and lists:

  • Two hands-free headsets.
  • Two removable protective boots.
  • Two carry cases.
  • Optical connector protection caps.
  • An instruction manual.
  • A 12-month warranty.

Therefore, the package provides a talk-set unit for each end of the communication path.

Additionally, confirm the supply of batteries, power adaptors and connection leads when ordering. This helps ensure your quotation covers the equipment and accessories required for your application.

Fibre Optic Talk Set – Knowledge Centre

Choosing the right Fibre Optic Talk Set involves understanding your communication requirements, available fibre path and connection arrangement. Therefore, this Knowledge Centre will bring together practical guidance to help you select and use talk sets effectively.

As the Knowledge Centre grows, we will add published articles under the categories below. These resources will support technicians, contractors and network operators planning communication between fibre endpoints.

Educational Guides

Our educational guides will explain how fibre optic talk sets work and when to use them.

Additionally, they will cover spare-fibre communication, full-duplex audio and the role of talk sets during installation and maintenance.

Technical Guides

Reliable communication starts with a suitable optical path. Therefore, our technical guides will explore singlemode fibre requirements, operating wavelengths, optical loss and communication distance.

They will also explain connector compatibility and the factors that influence talk-set performance.

Comparison Guides

Different projects require different communication arrangements. Accordingly, our comparison guides will examine fibre optic talk sets alongside other communication options.

These articles will help you assess each approach against your site access, available infrastructure and working requirements.

Procurement & Specification

Before ordering a fibre optic talk set, confirm the equipment and accessories your team needs.

Our procurement and specification guides will cover connection leads, optical interfaces, power arrangements and package contents. Consequently, you can prepare a clearer enquiry and select a complete working setup.

Setup & Operation Guides

Correct preparation helps technicians establish communication efficiently. Therefore, our setup and operation guides will cover fibre allocation, connection preparation, headset use and initial communication checks.

Additionally, they will explain how to maintain a dedicated voice path while working on other fibres.

Problem Solving

Communication difficulties can arise from several parts of the optical path. For this reason, our problem-solving guides will explore connection issues, excessive optical loss, interrupted fibre routes and power-related checks.

These articles will provide a structured approach to investigating unsuccessful or intermittent communication.

Equipment Care & Maintenance

Looking after your talk sets helps keep them ready for the next job. Accordingly, these guides will cover connector care, equipment inspection, battery management, transport and storage.

Additionally, they will explain practical checks before deploying equipment to site.

Industry Applications

Communication requirements vary between projects and working environments. Therefore, our application guides will explore talk-set use during telecommunications installation, campus network projects and fibre maintenance.

Each article will focus on planning communication around a suitable spare fibre and the tasks technicians need to coordinate.

Further Product Information

For more fibre optic product information, visit the Anderson Corporation YouTube Channel.

Frequently Asked Questions

What does a fibre optic talk set do?

A fibre optic talk set carries voice communication over a suitable optical fibre between two locations. Therefore, technicians can talk while working at opposite ends of the route.

The Yamasaki TT1315 uses a spare singlemode fibre for this purpose.

Can both technicians speak at the same time?

Yes. The TT1315 supports full-duplex digital audio, allowing both users to speak and listen simultaneously.

Additionally, the supplied headsets support hands-free operation.

Does the TT1315 require a mobile phone signal?

The talk-set voice connection travels through the optical fibre between the units. Therefore, that connection does not depend on mobile phone coverage.

However, both units still require power and a suitable continuous optical path.

Is the TT1315 suitable for multimode fibre?

The published product information specifies spare singlemode fibre. Therefore, select the TT1315 for that stated application and discuss other fibre types with Anderson Corporation before ordering.

Can I connect it to a fibre carrying network traffic?

The published information describes operation over a spare singlemode fibre. Therefore, plan a dedicated available fibre rather than assuming compatibility with a live service.

If your proposed route includes active equipment or other optical signals, discuss the arrangement before connecting the talk sets.

Will it work over every 100 km fibre route?

No. Although the datasheet lists a transmission distance of at least 100 km, actual suitability depends on the optical path and its total loss.

Therefore, provide route length, connection details and available loss measurements when seeking advice.

Which optical connector does it use?

The datasheet specifies FC/PC. Consequently, you will need suitable leads to connect the instruments to your installed fibre interfaces.

Additionally, confirm connector polish at each mating connection.

How long do the batteries last?

The datasheet lists five hours of battery operation. However, actual endurance depends on battery condition and operating conditions.

For longer tasks, plan the power arrangement before attending the site.

Can the talk set measure fibre link loss?

Use a suitable optical light source and power meter when you need insertion loss measurements. The TT1315’s principal role is voice communication between technicians.

Similarly, use an OTDR when you need trace-based information about events along a fibre route.

Does the package include both ends?

Yes. The TT1315 comes as a two-unit pack, with two headsets, two protective boots and two carry cases listed in the datasheet.

Additionally, confirm any required connection leads and power accessories when requesting your quotation.

Request Your Fibre Optic Talk Set Quote

The Yamasaki TT1315 Fibre Optic Talk Set helps technicians maintain voice contact over a spare singlemode fibre. Additionally, its full-duplex audio and hands-free headsets support coordination while working at separate endpoints.

To prepare your enquiry, include the route length, fibre availability and connector details. If available, also provide the measured link loss and your preferred power arrangement.

Request a Rapid Quote from Anderson Corporation for the TT1315 and the accessories required for your application.

Attachments

File File size
Yamasaki TT1315 Fibre Optic Talk Set 1,011 KB