The Yamasaki R142 Media Converter Chassis houses up to 14 compatible Yamasaki media converters in a 19-inch 2RU rack-mounted platform. Dual power supplies with automatic switch-over, two built-in cooling fans and hot-pluggable slots support organised installation and maintenance. Available in AC and −48 V DC versions.
| File | File size |
|---|---|
| Yamasaki R142 Media Converter Chassis | 897 KB |
The Yamasaki R142 Media Converter Chassis brings up to 14 compatible Yamasaki media converters into one central rack-mounted platform. It combines a 19-inch 2RU format with dual power supplies, automatic power supply switch-over and two built-in cooling fans. Additionally, hot-pluggable slots help technicians maintain individual converters within an organised installation.
As fibre links increase, separate converters can occupy valuable cabinet space and complicate power arrangements. Therefore, the R142 provides a practical way to consolidate compatible equipment in communications rooms and network cabinets.
The chassis supports the physical mounting and power requirements of the installed converters. However, each converter determines its own network interfaces, operating speed and supported fibre connection.
A media converter connects compatible transmission interfaces, such as copper Ethernet and optical fibre. A chassis provides a shared rack-mounted home for several compatible converters.
Consequently, the R142 helps installers organise multiple conversion points at a central location. Technicians can arrange their converters within a defined chassis footprint, which also simplifies equipment identification.
The R142 accommodates up to 14 compatible Yamasaki media converters. Furthermore, its modular arrangement allows an installation to start with fewer converters and expand as requirements develop.
This approach suits projects where several fibre links return to a common equipment cabinet. For example, a central communications room may serve separate buildings or remote Ethernet devices.
However, chassis capacity does not determine the number of Ethernet ports, available bandwidth or fibre distance. Those details depend on the selected converters and the complete link design.
The R142 combines equipment organisation with shared power and cooling features. Its documented features include:
Together, these features support a structured installation for multiple media conversion links. Additionally, centralising the converters can make equipment identification and routine access easier.
Before ordering, confirm the converter models, required power option and cabinet arrangement with Anderson Corporation. This helps ensure the proposed configuration matches the intended application.
Multiple standalone converters can create a crowded cabinet when each device needs its own mounting position and power connection. Therefore, physical organisation becomes more important as the network grows.
The R142 provides 14 converter positions within one rack-mounted chassis. As a result, installers can group compatible converters at the point where fibre links converge.
A consistent arrangement also helps technicians label connections and document the installation. For instance, a slot schedule can identify the remote location, converter model and associated patch-panel port.
Additionally, spare slots provide room for later expansion. A project can reserve positions for future links without installing every converter at the outset.
However, future expansion still requires a compatibility and power review. An empty slot alone does not establish that a proposed converter suits the chassis.
The R142 uses a 19-inch 2RU rack-mount format. Consequently, it fits the equipment-planning approach commonly used in communications cabinets.
A defined rack position helps designers coordinate the chassis with fibre enclosures, Ethernet switches and cable management. Furthermore, it keeps active conversion equipment within the same documented cabinet layout.
The datasheet lists chassis dimensions of 422 × 230 × 90 mm. Before finalising a cabinet drawing, confirm mounting clearances and the installed dimensions.
Allow additional space for connector access, cable routing and power connections. Similarly, check that the cabinet door closes without pressing against patch leads.
Rack planning should also consider access for maintenance. Therefore, position the chassis where technicians can identify slots and reach connections without disturbing neighbouring equipment.
The Yamasaki R142 includes dual power supplies with automatic switch-over. This provides an additional power supply path within the chassis.
Consequently, the design can reduce dependence on a single internal supply. However, actual continuity depends on the fault, the selected configuration and the upstream power arrangement.
Two internal supplies do not automatically provide protection from a complete site power outage. Likewise, a shared upstream power source can remain a common point of failure.
Where continuity matters, review the complete power path, including any UPS, distribution equipment and available supply feeds. Additionally, confirm how the selected chassis variant connects to the site supply.
This wider review helps match the chassis arrangement to the required service level. It also avoids treating internal power redundancy as a guarantee of uninterrupted network operation.
The R142 datasheet identifies two ordering options:
| Ordering Code | Power Option |
|---|---|
| R142 | AC 110–240 V |
| R142D | DC −48 V |
Therefore, specify the intended supply when requesting a quotation. The AC and DC versions should form part of the equipment schedule from the start.
For an existing cabinet, check the available supply before selecting the chassis. Additionally, confirm the proposed power connections and installation requirements.
The datasheet also lists AC 220 V dual power modules in its general specification table. Accordingly, confirm the applicable input specification for the exact supplied variant with Anderson Corporation.
For DC installations, provide the site supply details with your enquiry. This allows the proposed R142D configuration to receive a specific review before ordering.
The R142 provides hot-pluggable slots for compatible Yamasaki media converters. Therefore, technicians can access individual converter positions within the shared chassis.
This feature supports maintenance and changes within a multi-converter installation. Additionally, a clear slot schedule helps technicians identify the correct unit before starting work.
However, removing a converter interrupts the connection that uses that converter. Hot-pluggable hardware does not preserve traffic through a device that a technician has removed.
Before replacement, identify the affected service and follow the applicable equipment procedure. Furthermore, check the replacement converter’s model, interface and power compatibility.
For important services, plan a suitable maintenance window or an independently designed alternative path. The chassis feature supports equipment handling; service continuity requires a broader network design.
Two built-in cooling fans form part of the R142 chassis design. They support heat removal when compatible converters operate within the enclosure.
However, the surrounding cabinet must also provide suitable ventilation. A chassis fan cannot compensate for blocked airflow or excessive cabinet temperature.
Therefore, keep ventilation openings clear and consider nearby heat-producing equipment. Additionally, allow suitable cable-management space so patch leads do not obstruct ventilation.
The datasheet specifies a chassis operating temperature range of 0°C to +70°C. Nevertheless, the complete installation must remain within the limits of every installed component.
A converter with a narrower temperature range can restrict the usable system environment. Consequently, assess the chassis and converters together before approving a location.
For enclosed cabinets, consider the temperature inside the cabinet during operation. This can differ from the surrounding room temperature.
LED power indicators provide a visible reference for checking chassis power status. As a result, technicians can include them in an initial equipment inspection.
However, a power indication does not confirm that an Ethernet service operates correctly. The converter interfaces, fibre path and connected devices still require separate checks.
The R142 also includes circuit breaker protection. This forms part of the chassis electrical protection arrangement.
Nevertheless, circuit breaker protection does not establish protection against every electrical disturbance. For example, surge protection and upstream electrical coordination require their own assessment.
Therefore, specify the site power arrangement according to the installation requirements. Additionally, document how technicians should respond to a power fault before the equipment enters service.
The R142 is designed for Yamasaki media converters. However, confirm compatibility for the exact model and hardware version before ordering.
The datasheet lists the following converter references:
| Converter Reference | Datasheet Description |
|---|---|
| C102C | RJ45 to multimode SC, 2 km, Fast Ethernet |
| C102T | RJ45 to multimode ST, 2 km, Fast Ethernet |
| C225C | RJ45 to singlemode SC, 25 km, Fast Ethernet |
| C305C | RJ45 to multimode SC, 500 m, Gigabit Ethernet |
| C420C | RJ45 to singlemode SC, 20 km, Gigabit Ethernet |
| C400 | RJ45 to SFP |
These references help establish the intended converter families. However, they do not replace a review of current model availability and compatibility.
Similarly, a listed transmission distance does not guarantee operation over every installed fibre route. Fibre characteristics, connector losses and the selected optical interfaces still affect the link.
For SFP-based converters, confirm the permitted transceiver specifications separately. Additionally, check the remote equipment and fibre arrangement before choosing the optical modules.
The media converter chassis provides mounting, power and cooling functions. It does not assign a common Ethernet speed or optical reach to all installed units.
Instead, each converter and its optical interface determine the supported connection. Therefore, select the converter against the actual service requirement.
Check the copper interface speed, optical interface, fibre type and connector arrangement. Furthermore, confirm compatibility with the equipment at the opposite end.
For an SFP-based model, the transceiver selection also affects the optical connection. Consequently, the converter, SFP and remote device must work together.
A complete link review should account for the installed fibre path and connection losses. This helps prevent a chassis order from proceeding before the underlying converter selection is complete.
A central communications room may collect several separate fibre links. In this situation, the R142 can group compatible converters within one rack position.
Additionally, a documented slot layout helps maintenance teams associate equipment with remote locations. This becomes useful as the number of connections increases.
Separate buildings may require individual media conversion links at a common network location. Therefore, chassis-mounted converters can support a more organised central cabinet.
However, each building link still needs a suitable converter and optical design. Distances and fibre types may vary across the site.
The datasheet lists FTTH, FTTB and FTTx among its application areas. Suitability depends on the chosen converters and the network architecture.
Accordingly, confirm the required service interface before specifying the R142. A media converter chassis does not provide the functions of every access-network platform.
The datasheet also identifies ISP backhaul networking as an application area. Here, the chassis can centralise compatible media conversion equipment.
Nevertheless, throughput, resilience and service requirements must guide the complete equipment selection. The chassis alone does not establish a backhaul performance specification.
Start with a simple link schedule before selecting the final chassis configuration. For each connection, record the local interface, remote device, fibre type and required converter.
Next, assign a chassis position to each planned link. This makes the equipment layout easier to review before installation begins.
Additionally, record the associated fibre enclosure port and copper patching destination. Consistent labels reduce the time needed to trace a connection later.
Route patch leads so technicians can access individual converters. Furthermore, maintain the cable manufacturer’s bend-radius requirements and avoid loading connectors with cable tension.
Keep ventilation openings clear throughout the installation. Finally, update the equipment schedule after commissioning so the records match the installed arrangement.
Before applying power, check the chassis model against the equipment schedule. Additionally, confirm that the supply arrangement matches the selected AC or DC version.
Inspect the mounting arrangement and ensure the equipment sits securely within the cabinet. Then, check that power cables and patch leads have suitable support.
Verify each converter model against its assigned link. Furthermore, confirm the fibre connections, remote interfaces and any installed SFP modules.
After powering the equipment, check the chassis indicators and the status indicators on each converter. However, complete a functional link test before accepting the service.
Finally, record the installed converter positions and test results. These records provide a useful reference for later maintenance or expansion.
The following table summarises the supplied R142 datasheet.
| Specification | Published Detail |
|---|---|
| Product | Yamasaki R142 Media Converter Chassis |
| Rack format | 19-inch 2RU |
| Converter capacity | 14 slots |
| Intended equipment | Compatible Yamasaki standalone media converters |
| Power supplies | Dual supplies with automatic switch-over |
| Cooling | Two built-in fans |
| Slot feature | Hot-pluggable |
| Indication | LED power indicators |
| Protection | Circuit breaker protection |
| AC ordering option | R142, AC 110–240 V |
| DC ordering option | R142D, DC −48 V |
| Listed DC output | +5 V DC, 12 A |
| Operating temperature | 0°C to +70°C |
| Storage temperature | −40°C to +85°C |
| Relative humidity | 5% to 95% |
| Listed dimensions | 422 × 230 × 90 mm |
| Listed compliance references | CE, FCC, RoHS |
Before purchase, confirm the specifications for the selected variant and converter combination. Additionally, request supporting compliance documentation where the project requires it.
A complete enquiry helps Anderson Corporation review the proposed configuration. Therefore, include the following information when requesting pricing:
For an existing installation, include photographs or a current equipment schedule where available. Additionally, identify any converters that the new chassis will reuse.
Confirm the quotation scope before placing an order. In particular, establish whether it includes converters, SFPs, patch leads and any required installation accessories.
The R142 accommodates up to 14 compatible Yamasaki media converters. Additionally, you can plan spare positions for later expansion.
Confirm the supplied configuration when requesting a quotation. Chassis capacity describes the available positions; it does not establish which converters an order includes.
The datasheet describes support for combinations of Yamasaki media converter models. However, Anderson Corporation should confirm the exact proposed combination before supply.
Yes. The datasheet identifies hot-pluggable converter slots. However, removing a converter interrupts the service passing through that unit.
No. Dual supplies address part of the power arrangement. Consequently, upstream power loss, other equipment faults or link failures can still interrupt service.
Yes. The datasheet lists the R142D for DC −48 V supply arrangements. Therefore, identify the required power option in your enquiry.
No. Transmission distance depends on the selected converters, optical interfaces and fibre link. Accordingly, assess those components before finalising the configuration.
The supplied datasheet does not establish an outdoor ingress-protection rating. Therefore, do not specify it for exposed outdoor installation without a separate suitability assessment.
The supplied datasheet describes a media converter chassis. It does not document shared Ethernet switching or central network-management functions.
Yes, subject to available slots and confirmed compatibility. Additionally, review the power and cooling requirements before expanding an existing installation.
The Media Converter Chassis Knowledge Centre will bring together practical guidance on selecting, installing and maintaining chassis-mounted media converters.
Future articles will explain how converter type, slot requirements and interface selection influence chassis planning. Additionally, they will explore the information needed to assess an existing converter installation.
This section will cover AC and DC power arrangements, dual power supplies and upstream power planning. Furthermore, it will explain how chassis power features fit within a wider service-continuity strategy.
Upcoming resources will examine cabinet layout, ventilation, equipment access and cable management. Consequently, installers will have a central place to find guidance for organised chassis installations.
Future articles will address hot swapping, converter replacement, fault investigation and spare-slot planning. Additionally, they will discuss the documentation that supports ongoing maintenance.
Links to new satellite articles will appear in the relevant sections as they are published.
Download the Yamasaki R142 Media Converter Chassis datasheet to review the published features, specifications and ordering references.
Additionally, visit the Anderson Corporation YouTube Channel for fibre optic product videos and technical information.
Contact Anderson Corporation to discuss the Yamasaki R142 Media Converter Chassis for your installation. Include your converter models, planned link count and available power supply so the proposed configuration can receive a practical review.
Whether you are consolidating existing converters or planning new links, start with a clear equipment schedule. This helps match the chassis, converters and power option to the project.
Phone: +61 3 9761 7600
Email: sales@andcorp.com.au
| File | File size |
|---|---|
| Yamasaki R142 Media Converter Chassis | 897 KB |