High Strength Loose Tube Fibre Optic Cable

RapidConnect® H-Series High Strength Loose Tube Fibre Optic Cable is engineered for direct burial in reactive and expansive soils. Its reinforced construction provides 6.0 kN tensile strength, high crush resistance, axial compression resistance and dry core water blocking. Available in OS2 Singlemode and OM4 Multimode from 2 to 144 fibres.

Attachments

File File size
High-Strength-Loose-Tube-Cable-H-Series 2 MB

High Strength Loose Tube Fibre Optic Cable

High Strength Loose Tube Fibre Optic Cable provides the mechanical protection required for demanding underground telecommunications networks. The RapidConnect® H‑Series combines a reinforced loose tube construction with high tensile strength, crush resistance, dry core water blocking and a bonded blue nylon outer jacket.

More importantly, the H‑Series is engineered for direct burial in reactive and expansive soils. These soil conditions can place conventional underground cables under significant compression, shear and lateral movement. Therefore, the cable must withstand more than the pulling forces applied during installation.

Available with OS2 Singlemode and OM4 Multimode optical fibre, the RapidConnect® H‑Series supports fibre counts from 2 to 144 fibres. As a result, it provides a versatile solution for telecommunications backbones, transport infrastructure, utilities, industrial networks and other critical underground fibre systems.

RapidConnect® H‑Series at a Glance

  • High-strength multi-loose-tube construction
  • Engineered for direct burial
  • Designed for reactive and expansive soil environments
  • 6.0 kN maximum tensile strength
  • 6.0 kN/100 mm short-term crush resistance
  • 3.0 kN/100 mm long-term crush resistance
  • Enhanced axial compression resistance
  • High shear and compression resistance
  • GRP central strength member
  • Gel-filled active buffer tubes
  • Dry water-swellable cable core
  • Bonded polyethylene and blue polyamide jacket system
  • Anti-termite outer protection
  • UV-stabilised blue nylon outer jacket
  • Fibre counts from 2 to 144
  • OS2 Singlemode and OM4 Multimode options
  • Suitable for qualifying RapidConnect® 25-Year Enterprise Cabling Infrastructure System Warranty projects

Engineered for Reactive and Expansive Soils

Underground fibre optic cable can face significant forces throughout its service life. In particular, reactive soils expand when moisture levels increase and contract as they dry. This continuing movement can place a directly buried cable under axial compression, lateral pressure and shear forces.

Black soils and other expansive clay soils can present an especially difficult environment. Although a cable may perform well during a conventional pulling or crush test, it may not tolerate the longitudinal forces generated by ongoing ground movement.

The RapidConnect® H‑Series addresses this challenge through a mechanically reinforced construction designed for high shear, compression and tensile performance. Consequently, it is suited to direct-burial routes where soil movement forms an important part of the cable-selection process.

However, every underground route remains different. Ground conditions, installation depth, trench preparation, backfill, mechanical protection, rodents and future excavation risks must all form part of the project design.

What Makes the H‑Series a High Strength Fibre Optic Cable?

The term “high strength” should describe measurable cable performance rather than a general claim of durability.

The RapidConnect® H‑Series achieves its mechanical performance through several coordinated design elements:

  • A glass-reinforced plastic central strength member
  • SZ-stranded buffer tubes and fillers
  • A reinforced polyethylene sheath
  • An integrally bonded polyamide outer jacket
  • High tensile performance during installation
  • High short-term and long-term crush resistance
  • Resistance to axial compression and shear forces
  • Controlled loaded and unloaded bend radii

Together, these elements help the cable withstand installation loads and long-term underground forces. Meanwhile, the loose tube design protects the optical fibres from direct mechanical strain.

Multi-Loose-Tube Cable Construction

The H‑Series uses a stranded multi-loose-tube construction. This design separates the optical fibres from the cable’s primary mechanical load-bearing components.

Each active thermoplastic buffer tube contains up to 12 optical fibres. In addition, a low-viscosity, thixotropic and non-melting gel protects the fibres within the tube.

The required buffer tubes and fillers are then SZ-stranded around the central strength member. This stranded arrangement allows the cable to accommodate mechanical and temperature-related movement while helping to isolate the optical fibres from strain.

Therefore, the optical fibres do not carry the cable’s installation load. Instead, the cable structure manages the mechanical forces while the fibres remain protected inside the buffer tubes.

GRP Central Strength Member

A glass-reinforced plastic central strength member forms the mechanical centre of the H‑Series construction.

The surrounding buffer tubes and fillers are stranded around this central member. As a result, the GRP element supports the cable structure and helps control tensile strain during hauling and installation.

GRP also provides mechanical reinforcement without introducing a metallic central conductor. Therefore, the construction avoids the earthing and bonding requirements commonly associated with metallic strength elements.

However, cable selection must still consider the entire installed system. Metallic enclosures, draw wires, armour, pathway components and nearby electrical infrastructure may introduce separate bonding or separation requirements.

6.0 kN Maximum Tensile Strength

The H‑Series has a published maximum tensile strength of 6.0 kN across the listed fibre-count configurations.

This rating provides additional mechanical capacity for demanding installation conditions. For example, longer routes, multiple bends, changes in elevation and high-friction pathways can increase the tension placed on a cable during installation.

Nevertheless, the 6.0 kN value remains a maximum cable rating. It should never become the planned operating point for a cable pull.

Before installation, the contractor should develop a pull plan that considers:

  • Cable weight
  • Route length
  • Number and angle of bends
  • Conduit or trench geometry
  • Coefficient of friction
  • Entry and exit points
  • Pulling equipment
  • Cable grip selection
  • Swivel requirements
  • Pulling lubricant
  • Maximum sidewall pressure
  • Loaded bend radius
  • Safety margin

Furthermore, installers should monitor pulling tension during demanding cable pulls. This approach helps prevent an unexpected obstruction, tight bend or equipment problem from exceeding the cable rating.

High Crush Resistance

Underground cables may experience concentrated loads during installation and throughout their working life. Therefore, crush resistance forms an important part of direct-burial cable selection.

The RapidConnect® H‑Series provides:

  • 6.0 kN/100 mm short-term crush resistance
  • 3.0 kN/100 mm long-term crush resistance

Short-term crush resistance relates to temporary mechanical loading. For example, a cable may experience short-duration pressure during handling, installation or backfilling.

In contrast, long-term crush resistance considers loads that remain on the cable for an extended period. These may result from ground pressure, poorly selected backfill, external infrastructure or localised loading.

However, a strong cable does not replace correct civil construction. Installers must still prepare the trench, remove sharp objects, select suitable backfill and maintain the specified burial depth.

Axial Compression Resistance

Tensile testing measures how a cable responds when pulled. Crush testing measures how it responds to an external load applied across a defined section. However, neither test completely represents the forces created when reactive soil expands and pushes along the cable route.

Axial compression occurs when longitudinal movement forces the cable structure together. If the cable cannot manage this compression, it may buckle or move laterally. Subsequently, the cable structure may place stress on the buffer tubes and optical fibres.

The H‑Series design has been qualified under an enhanced axial compression test that applies a 4 kN axial load while monitoring optical performance.

The test considers:

  • Axial compression of the cable
  • Controlled lateral deviation
  • Physical cable condition
  • Changes in optical attenuation
  • Performance at a wavelength sensitive to bending effects

The acceptance criteria require no physical damage and no change in attenuation during the test. Therefore, axial compression performance represents one of the defining differences between the H‑Series and a conventional underground loose tube cable.

Shear Resistance in Moving Ground

Shear force occurs when different parts of the surrounding ground move in different directions. For example, one section of soil may rise, settle or move laterally while the adjacent section remains relatively stable.

This movement can create a concentrated load across a short length of buried cable. Consequently, the cable may face bending, compression and lateral displacement at the same location.

The reinforced H‑Series construction helps manage these combined mechanical forces. For this reason, it is particularly relevant when route investigations identify reactive clay, expansive black soil or other ground-movement risks.

Nevertheless, cable strength represents only one part of the solution. Engineers should also consider trench design, bedding materials, route drainage, installation depth and local geotechnical advice.

Dry Water Blocking with Gel-Filled Buffer Tubes

The H‑Series combines two complementary moisture-management systems.

First, water-swellable materials provide longitudinal water blocking around the cable core. If water enters through a localised sheath breach, these materials swell and help restrict further migration along the cable.

Second, each active buffer tube contains a low-viscosity thixotropic gel. This gel protects the optical fibres inside the tube and limits moisture movement around the fibres.

Therefore, the H‑Series has a dry water-blocked cable core, but it is not a completely gel-free cable. This distinction matters when specifying, preparing and terminating the cable.

The dry core also simplifies access compared with constructions that fill the entire cable core with flooding compound. However, technicians must still clean and prepare the gel-filled buffer tubes correctly during splicing.

Water-Penetration Performance

The H‑Series water-blocking system has been assessed using the IEC 60794 water-penetration method for outdoor optical cables.

The test uses:

  • A 3-metre cable sample
  • A 1-metre water head
  • A 24-hour test period
  • No water leakage as the acceptance criterion

This testing provides evidence of longitudinal water-blocking performance. However, it does not mean that installers can leave open cable ends exposed to water.

During transport, storage and installation, both cable ends should remain sealed. In addition, technicians should reseal any unterminated cable end immediately after cutting.

Bonded Polyethylene and Polyamide Jacket System

The H‑Series uses a polyethylene sheath beneath a UV-stabilised blue polyamide outer jacket. These layers are integrally bonded to form a stable jacket system.

The bonded construction helps prevent the outer nylon layer from wrinkling when the cable bends. As a result, the jacket retains a consistent external surface while supporting handling and installation.

The blue polyamide layer also provides a relatively low-friction surface. Therefore, it can assist cable movement during duct hauling and handling. However, installers must still follow the approved pulling plan and lubricant requirements.

Two ripcords sit beneath the sheath to help technicians access the internal cable structure during preparation.

Anti-Termite Protection

Termites can threaten polymeric cable jackets in some Australian environments. Therefore, the H‑Series uses a blue polyamide outer jacket that provides an additional anti-termite barrier.

The nylon layer also contributes to:

  • Surface hardness
  • Abrasion resistance
  • UV protection
  • Reduced surface friction
  • Protection of the underlying polyethylene sheath

However, no cable should be described as indestructible. Route conditions, installation damage and exposure to other pests can still affect the cable.

Where rodents represent the dominant risk, consider the RapidConnect® GRP Armoured Rodent Proof Fibre Optic Cable or RapidConnect® CST Armoured Rodent Proof Fibre Optic Cable.

Fibre Counts and Cable Dimensions

The RapidConnect® H‑Series accommodates small, medium and large underground fibre backbones.

Number of fibres Number of elements Nominal cable diameter Nominal cable weight
2–72 6 14.8 mm 175 kg/km
96 8 17.4 mm 240 kg/km
120 10 19.9 mm 305 kg/km
144 12 23.0 mm 395 kg/km

The selected fibre count affects cable diameter, cable weight, drum selection and installation planning. Therefore, designers should not base hauling calculations on a generic H‑Series value.

Instead, use the specifications for the exact fibre count being supplied.

Mechanical Specifications

Performance characteristic H‑Series specification
Maximum tensile strength 6.0 kN
Short-term crush resistance 6.0 kN/100 mm
Long-term crush resistance 3.0 kN/100 mm
Minimum bend radius under load 30 × cable OD
Minimum bend radius without load 15 × cable OD
Operating temperature −10°C to +70°C

The minimum bend radius changes with cable diameter. For example, a 14.8 mm cable requires less space than a 23.0 mm cable.

Consequently, the project designer must consider the actual cable diameter when selecting pits, conduits, hauling equipment, drum stands and route transitions.

Mechanical and Environmental Testing

The H‑Series design has been assessed against a broad set of optical cable tests.

These include:

  • Tube kinking
  • Tensile performance
  • Crush resistance
  • Impact resistance
  • Torsion
  • Repeated bending
  • Bending under tension
  • Temperature cycling
  • Accelerated cable ageing
  • Compression and shear resistance
  • Water penetration
  • Axial compression resistance

Throughout these tests, the acceptance criteria consider both physical condition and optical performance. Therefore, the cable must protect the fibres without producing an unacceptable attenuation change.

Standards and Australian Cabling Requirements

The H‑Series cable design references IEC 60794-3 for outdoor optical fibre cable. In addition, the product is designed with reference to AS/CA S008 requirements for customer cabling products.

Australian telecommunications projects may also need to comply with installation requirements, carrier specifications, project standards and site-specific engineering requirements.

The Australian Telecommunications Alliance maintains the current publication register for AS/CA S008 and other Australian customer-cabling standards.

However, product compliance does not automatically make every installation compliant. A registered cabler and the project designer must assess the complete installation.

OS2 Singlemode and OM4 Multimode Options

The H‑Series is available with OS2 Singlemode and OM4 Multimode fibre.

OS2 Singlemode

OS2 Singlemode fibre suits long-distance and high-bandwidth telecommunications backbones. Therefore, it is generally the preferred choice for:

  • Campus backbone networks
  • Carrier and telecommunications infrastructure
  • Utility communications
  • Transport corridors
  • Regional networks
  • Industrial backbone systems
  • Connections between widely separated facilities

The optical transmission distance depends on the active equipment, wavelength, connector loss, splice loss and total channel-loss budget. It does not depend on cable tensile strength.

OM4 Multimode

OM4 Multimode fibre supports high-speed Ethernet over shorter distances. As a result, it may suit underground links within:

  • Large campuses
  • Industrial sites
  • Processing facilities
  • Warehousing precincts
  • Local infrastructure compounds
  • Facilities using existing multimode networks

Before selecting OM4, confirm the required data rate, optical transceivers, total channel length and future network requirements.

Direct Burial Installation Considerations

Although the H‑Series is engineered for direct burial, correct installation remains critical.

Route investigation

Before construction begins, investigate:

  • Soil classification
  • Reactive or expansive clay
  • Rock and sharp inclusions
  • Drainage
  • Groundwater
  • Existing services
  • Vehicle loading
  • Future excavation risks
  • Termite exposure
  • Rodent exposure

Trench preparation

Prepare the trench so that the cable does not rest against sharp rocks, construction waste or other damaging objects.

Where required, use suitable bedding and selected backfill. In addition, maintain the specified separation from other services.

Cable handling

Use drum stands and handling equipment appropriate for the cable weight and drum size. Furthermore, maintain the correct direction of drum rotation.

Do not drag the cable across the ground or allow it to develop uncontrolled loops. Similarly, avoid twisting the cable during installation.

Pulling tension

Use an approved pulling grip and swivel arrangement. In demanding installations, monitor the applied tension.

The pulling system must transfer the load into the cable structure correctly. Therefore, do not attach pulling equipment directly to the optical fibres or buffer tubes.

Bend radius

Maintain at least 30 times the cable diameter while the cable remains under load. After installation and removal of the pulling load, maintain at least 15 times the cable diameter.

These values apply to the supplied H‑Series cable. However, the project may specify a larger radius.

Cable-end sealing

Keep both cable ends sealed throughout delivery, storage and installation. After cutting the cable, reseal any exposed end immediately.

This prevents water from entering the buffer tubes or cable core before termination.

Testing and records

After installation, complete the required optical tests and record the results.

Depending on the project, testing may include:

  • Continuity and polarity
  • Insertion loss
  • Optical return loss
  • Bidirectional OTDR testing
  • Splice-loss measurement
  • Link-length verification
  • End-face inspection

Keep the test results with the cable drum information, route records and as-built documentation.

Where to Use High Strength Loose Tube Fibre Optic Cable

The RapidConnect® H‑Series suits projects where direct-burial capability and resistance to soil-generated mechanical forces are important.

Typical applications include:

  • Telecommunications backbone networks
  • Direct-burial campus connections
  • Utility communications
  • Transport infrastructure
  • Rail and road communication corridors
  • Industrial facilities
  • Processing sites
  • Regional telecommunications routes
  • Renewable energy projects
  • Water and wastewater infrastructure
  • Government infrastructure
  • High-fibre-count underground networks
  • Routes through reactive or expansive soils

However, applications such as mining, rail, power utilities and transport infrastructure may impose additional standards or project-specific requirements. Therefore, confirm the complete specification before ordering.

Choosing the Right RapidConnect® Fibre Optic Cable

Different cable constructions manage different environmental and installation risks.

Project requirement Recommended RapidConnect® cable
Direct burial in reactive or expansive soil H‑Series High Strength Loose Tube Fibre Optic Cable
Outdoor conduit or duct installation TR‑Series Mini Loose Tube Fibre Optic Cable
Non-metallic rodent protection GRP Armoured Rodent Proof Fibre Optic Cable
Steel armoured rodent and impact protection CST Armoured Rodent Proof Fibre Optic Cable
Self-supporting aerial installation A‑Series ADSS Fibre Optic Cable
Indoor and protected external commercial pathways W‑Series Indoor/Outdoor Fibre Optic Cable
Factory-terminated installation Pre-Terminated Fibre Optic Cable

The H‑Series does not replace every other outdoor fibre cable. Instead, it addresses the specific mechanical challenges associated with demanding direct-burial routes and ground movement.

High Strength Cable Versus Armoured Cable

High strength and armour describe different forms of protection.

The H‑Series focuses on tensile, crush, shear and axial compression performance. Therefore, it suits direct-burial installations where soil movement and mechanical loading drive the cable specification.

In contrast, GRP or steel armour primarily addresses rodent attack, impact and penetration risks.

A project may face both soil movement and rodent exposure. In that case, the designer must determine which construction provides the required combination of mechanical and pest protection. Do not assume that high tensile strength automatically provides rodent resistance.

High Strength Cable Versus Mini Loose Tube Cable

The RapidConnect® TR‑Series Mini Loose Tube Fibre Optic Cable provides a compact, lightweight solution for outdoor conduit and duct installations.

By comparison, the H‑Series has a larger and more mechanically reinforced construction. It is designed for direct burial and demanding soil conditions.

Choose the TR‑Series when conduit capacity, low cable weight and compact construction lead the specification. However, select the H‑Series when direct burial, axial compression, shear resistance and higher mechanical performance become the priority.

High Strength Cable Versus ADSS Cable

The RapidConnect® A‑Series ADSS Fibre Optic Cable is engineered for self-supporting aerial spans between suitable structures.

The H‑Series serves a completely different purpose. It is an underground direct-burial cable and should not be used as a substitute for an engineered aerial cable.

Similarly, the tensile rating of an underground cable does not provide an aerial span rating. Aerial installations require span, sag, tension, wind, temperature and attachment calculations.

High Strength Cable Versus Indoor/Outdoor Cable

The RapidConnect® W‑Series Indoor/Outdoor Fibre Optic Cable uses a tight-buffered construction with a black UV-resistant LSZH outer jacket. It suits indoor and protected external commercial pathways.

In contrast, the H‑Series uses a stranded loose tube construction and targets direct-burial underground infrastructure.

Therefore, the correct choice depends on the pathway. Use the W‑Series where indoor transition and termination simplicity matter. Meanwhile, use the H‑Series where the underground environment requires substantially greater mechanical performance.

Installation Lengths and Drum Planning

Large infrastructure projects may require long cable lengths to reduce intermediate joints. Fewer joints can simplify construction and reduce the number of splice closures, pits and optical connection points.

However, the maximum manufacturing length and the practical installation length are not the same.

The final drum length depends on:

  • Fibre count
  • Cable diameter
  • Cable weight
  • Drum capacity
  • Transport limitations
  • Route design
  • Pulling equipment
  • Maximum calculated tension
  • Available access points
  • Project handling requirements

Anderson Corporation can review the route requirements and coordinate suitable manufacturing and delivery lengths. Nevertheless, every pull must remain within the cable’s mechanical limits.

RapidConnect® 25-Year System Warranty

The H‑Series can form part of a qualifying RapidConnect® 25-Year Enterprise Cabling Infrastructure System Warranty.

Warranty eligibility depends on the complete system, product selection, installation, testing, documentation and applicable program requirements.

Therefore, contact Anderson Corporation before installation if the project requires warranty coverage. This allows the cable, connectivity, installation method and test documentation to be aligned from the beginning.

Specifying RapidConnect® H‑Series Cable

A complete project specification should identify:

  • RapidConnect® H‑Series High Strength Loose Tube Fibre Optic Cable
  • Required fibre category
  • Required fibre count
  • Direct-burial route conditions
  • Soil classification
  • Mechanical performance requirements
  • Maximum installation tension
  • Short-term and long-term crush resistance
  • Minimum loaded and unloaded bend radius
  • Water-blocking requirements
  • Anti-termite requirements
  • Cable marking
  • Drum length
  • Testing requirements
  • Compliance requirements
  • Warranty requirements
  • Delivery location and timing

Avoid specifying only “outdoor fibre optic cable”. That description does not define direct-burial capability, mechanical performance or suitability for reactive soils.

High Strength Loose Tube Fibre Optic Cable – Knowledge Centre

Choosing the right High Strength Loose Tube Fibre Optic Cable involves far more than selecting a fibre count or comparing cable diameters. Instead, successful direct-burial fibre projects require an understanding of soil movement, axial compression, shear forces, tensile loading, crush resistance, moisture and installation practices.

That is why Anderson Corporation is developing one of Australia’s most comprehensive knowledge centres dedicated to high-strength loose tube fibre optic cable and direct-burial fibre infrastructure.

Whether you are designing a telecommunications backbone, utility network, transport corridor or industrial fibre system, our technical articles will help you make informed engineering decisions.

As our Knowledge Centre grows, you will find practical guidance covering every stage of H‑Series selection, specification, installation and lifecycle management.

Educational Guides

If you are new to high-strength loose tube fibre optic cable, our educational guides will explain the principles behind reinforced direct-burial cable construction.

In particular, you will learn how a multi-loose-tube design protects optical fibres against tensile strain, axial compression and movement within reactive soils. Furthermore, these articles will explain when a project requires high-strength cable and when another cable construction may provide a better solution.

Articles Coming Soon

Technical Guides

Once you understand the fundamentals, you can explore the engineering that differentiates high-strength underground fibre optic cables.

For example, our technical guides will examine GRP central strength members, SZ-stranded buffer tubes, tensile strength, crush resistance, axial compression resistance and dry core water blocking.

Furthermore, these resources will explain how each cable component contributes to mechanical performance in reactive and expansive soil environments.

Articles Coming Soon

Comparison Guides

Sometimes selecting the right fibre optic cable requires a clear understanding of the available alternatives.

Therefore, our comparison guides will examine how high-strength loose tube fibre optic cable differs from standard loose tube cable, CST armoured cable, GRP armoured cable, Mini Loose Tube Fibre Optic Cable and Indoor/Outdoor Fibre Optic Cable.

As a result, engineers, consultants and contractors will be able to compare direct-burial capability, mechanical strength, rodent protection, cable dimensions and installation requirements more confidently.

Articles Coming Soon

Procurement & Specification

Before purchasing any high-strength fibre optic cable, project teams should understand the engineering requirements that influence long-term underground performance.

Accordingly, our procurement and specification guides will explain how to evaluate fibre count, fibre category, soil conditions, tensile strength, crush resistance, axial compression performance, cable diameter and required drum lengths.

In addition, these resources will help consultants and asset owners prepare clearer cable specifications and avoid treating every outdoor loose tube cable as suitable for demanding direct-burial conditions.

Articles Coming Soon

Direct-Burial Installation Guides

Even the strongest underground fibre optic cable requires correct installation.

Consequently, our installation guides will focus on practical field techniques that help contractors protect the cable while maintaining its specified bend radius and pulling-tension limits.

Whether the project involves reactive soil, expansive clay, long underground routes or high-fibre-count infrastructure, these articles will provide practical guidance for route investigation, trench preparation, hauling, backfilling, jointing and testing.

Articles Coming Soon

Reactive Soil & Ground Movement

Reactive and expansive soils create mechanical challenges that conventional cable-selection methods may overlook.

As moisture levels change, these soils can expand, contract and move. Consequently, a directly buried cable may experience axial compression, shear forces, lateral displacement and localised bending.

Our reactive-soil guides will explain how these forces affect underground fibre cable and why tensile strength alone does not determine long-term survivability.

Articles Coming Soon

Problem Solving

Underground fibre networks can experience failures that require detailed investigation.

Rather than simply replacing the damaged cable, identifying the underlying cause can help prevent the same problem from affecting the replacement infrastructure.

For this reason, our problem-solving articles will examine soil movement, axial compression, excessive pulling tension, crushing forces, moisture, poor trench preparation, unsuitable backfill and other common causes of direct-burial cable failure.

Articles Coming Soon

Lifecycle & Asset Management

Installing high-strength underground fibre optic cable represents a long-term infrastructure investment.

Therefore, asset owners increasingly evaluate cable systems according to reliability, maintenance requirements and total cost of ownership rather than initial cable price alone.

Our lifecycle and asset-management articles will examine underground survivability, route documentation, spare fibre capacity, joint reduction, inspection planning, network resilience and future replacement costs.

Ultimately, these resources will help organisations maximise the value of their direct-burial fibre infrastructure.

Articles Coming Soon

Industry Applications

Every industry presents different underground infrastructure challenges.

For example, transport and utility networks may cross long sections of reactive soil. Meanwhile, industrial and telecommunications projects may prioritise high fibre counts, mechanical strength, network reliability and reduced intermediate jointing.

Accordingly, our industry application articles will explain how RapidConnect® H‑Series High Strength Loose Tube Fibre Optic Cable supports demanding Australian underground networks.

These resources will cover telecommunications backbones, transport corridors, utility networks, industrial facilities, renewable energy projects, regional infrastructure and critical communications systems.

Articles Coming Soon

Frequently Asked Questions

What is High Strength Loose Tube Fibre Optic Cable?

High Strength Loose Tube Fibre Optic Cable is a mechanically reinforced outdoor cable designed to protect optical fibres during demanding installation and underground service conditions.

The RapidConnect® H‑Series combines a multi-loose-tube construction with 6.0 kN tensile strength, high crush resistance and enhanced axial compression performance.

Is the H‑Series suitable for direct burial?

Yes. The H‑Series is engineered for direct burial, including routes through reactive and expansive soils.

However, the complete installation must still account for trench preparation, burial depth, backfill, drainage, rodents, other services and project requirements.

What is reactive soil?

Reactive soil changes volume as its moisture content changes. It may expand when wet and contract as it dries.

This movement can exert compression and shear forces on a directly buried cable. Therefore, reactive-soil installations may require a cable specifically designed to manage those forces.

What does axial compression mean?

Axial compression is a force that pushes along the length of the cable. If the cable cannot manage this force, it may buckle or move laterally.

The H‑Series has been designed and tested to resist the effects of axial compression while protecting its optical performance.

What is the maximum pulling tension?

The published maximum tensile strength is 6.0 kN.

Nevertheless, installers should use an engineered pulling plan and appropriate safety margin. The calculated installation tension should remain below the maximum rating.

Is the H‑Series rodent proof?

The standard H‑Series should not be selected primarily as a rodent-proof cable.

Where rodents present a significant risk, consider the RapidConnect® GRP or CST armoured fibre cable range.

Is the cable completely dry?

The cable uses dry water-swellable materials around the stranded cable core. However, the active buffer tubes contain thixotropic gel.

Therefore, it is best described as a dry water-blocked core with gel-filled buffer tubes.

Does the nylon jacket provide termite protection?

Yes. The blue polyamide outer jacket provides an anti-termite barrier. It also supports UV stability, abrasion resistance and reduced surface friction.

Is the H‑Series metallic?

The published core construction uses a GRP central strength member rather than a metallic central strength member.

However, confirm the supplied configuration and complete installed system before making project-wide electrical or bonding decisions.

Can the H‑Series be installed aerially?

No aerial span capability should be inferred from its tensile rating.

For self-supporting aerial installations, use a properly engineered ADSS Fibre Optic Cable.

Is the H‑Series suitable for indoor installation?

The H‑Series is primarily an outdoor direct-burial cable. Its polyethylene and nylon jacket system should not automatically be treated as suitable for unrestricted installation inside buildings.

Where the cable enters a building, assess the applicable cabling and fire requirements. A transition to an appropriate indoor cable may be required.

Is OS2 or OM4 the better choice?

OS2 generally suits longer-distance and future-focused infrastructure backbones. Meanwhile, OM4 may suit shorter links that use multimode Ethernet equipment.

The correct selection depends on transmission distance, equipment, loss budget and future network strategy.

How many fibres are available?

The H‑Series supports configurations from 2 to 144 fibres.

Availability, manufacturing quantities and delivery timing should be confirmed with Anderson Corporation.

Can long cable lengths eliminate intermediate splices?

Longer cable lengths can reduce intermediate joints. However, the practical installation length depends on the cable weight, route geometry, pulling tension, drum capacity and site access.

Therefore, complete a route and pulling assessment before finalising drum lengths.

High Strength Loose Tube Fibre Optic Cable Knowledge Centre

Choosing a High Strength Loose Tube Fibre Optic Cable involves more than selecting a fibre count. Successful direct-burial networks require an understanding of soil movement, tensile loading, axial compression, shear forces, crush resistance, water blocking, cable handling and long-term underground performance.

That is why Anderson Corporation is developing a dedicated technical knowledge centre for high-strength direct-burial fibre infrastructure.

Whether you are designing a telecommunications backbone, utility network, transport corridor or industrial fibre system, the H‑Series Knowledge Centre will help project teams understand the engineering factors behind reliable underground cable selection.

Discuss Your Underground Fibre Project

The RapidConnect® H‑Series provides a specialised solution for direct-burial networks exposed to demanding mechanical and soil conditions.

However, correct cable selection depends on the complete route. Fibre count, soil conditions, pulling tension, bend radius, installation method, rodent exposure and required drum lengths should all be reviewed before ordering.

Contact Anderson Corporation to discuss your project, confirm the required H‑Series configuration or request a project-specific quotation.

Attachments

File File size
High-Strength-Loose-Tube-Cable-H-Series 2 MB