1RU Rackmount Sliding Fibre Enclosure

The RapidConnect 148S 1RU Rackmount Sliding Fibre Enclosure provides organised fibre termination and up to 72-fibre splice capacity. Its sliding tray, dual splice cassettes and configurable SC or LC faceplates provide convenient access and flexible network deployment.

SKU: 148S

Attachments

File File size
148S Rackmount Sliding Enclosure 2 MB

1RU Rackmount Sliding Fibre Enclosure

The 1RU Rackmount Sliding Fibre Enclosure provides a compact and configurable platform for terminating, splicing, protecting and managing optical fibres within a standard rack or cabinet. Designed for professional fibre installations, the RapidConnect 148S combines a sliding tray, dual splice cassettes and interchangeable faceplate options within a space-efficient 1RU enclosure.

Because the 148S is supplied unloaded, installers can select the faceplates, fibre adaptors and pigtails required for each project. Therefore, the same enclosure can support different connector types, fibre modes and termination configurations without forcing customers into a predetermined layout.

Moreover, the sliding design gives technicians direct access to the internal fibre management area. As a result, they can install, inspect and maintain fibres without removing the complete enclosure from the rack.

Product code: 148S
Rack height: 1RU
Configuration: Unloaded
Maximum splice capacity: Up to 72 fibres

Request a Quote

What Is the RapidConnect 148S 1RU Rackmount Sliding Fibre Enclosure?

The RapidConnect 148S is an unloaded 1RU enclosure for rackmount fibre termination and cable management. It provides a protected location for incoming fibre optic cables, fusion splices, pigtails, adaptors and outgoing fibre patch leads.

First, the incoming cable enters the rear of the enclosure. The installer then secures and routes the cable within the internal management area. Next, the individual fibres connect to pigtails through fusion splicing or another approved termination method. Finally, the pigtail connectors connect to the adaptors installed in the selected front faceplate.

Because the enclosure separates incoming cable, protected splices and front-panel connections, it creates an organised transition between the installed fibre cable and active network equipment. Consequently, technicians can identify, test and maintain individual fibre circuits more efficiently.

The enclosure can support up to 72 spliced fibres when correctly configured. However, the final presented-fibre capacity depends on the selected faceplate, adaptor type and internal splice arrangement. Therefore, customers should confirm the complete configuration before ordering.

Why Use a Sliding Fibre Enclosure?

Rackmounted fibre enclosures generally use either a fixed or sliding internal platform. Although both designs protect fibre connections, a sliding enclosure provides easier access to internal components.

The 148S tray slides forward from the rack. Therefore, an installer can access the splice cassettes, fibre routing and rear of the adaptor faceplate while the enclosure remains mounted. This design can simplify initial termination work and later maintenance.

Additionally, direct access reduces the need to reach through adjacent rack equipment. As a result, technicians can work more carefully around delicate fibres and connections.

A sliding enclosure can provide several practical benefits:

  • Easier access to internal splice cassettes
  • More convenient fibre routing and identification
  • Faster inspection of installed connections
  • Simpler additions, changes and maintenance
  • Reduced need to remove the enclosure from the rack
  • Better control of fibre movement during servicing
  • Efficient use of limited rack space

However, technicians must still handle the tray carefully. Before opening it, they should check that incoming cables and patch leads have enough controlled movement. They should also confirm that the surrounding rack equipment does not obstruct the tray.

Compact 1RU Fibre Management

Rack space is valuable in communications rooms, data cabinets and equipment racks. Therefore, the 148S uses a compact 1RU format while still providing internal space for fibre routing and splicing.

One rack unit measures approximately 44.45 mm in height. Accordingly, the 148S has an unpacked height of 44 mm and occupies one standard rack unit.

This compact format makes the enclosure suitable for installations where the designer must balance fibre capacity against available cabinet space. For example, it may support building backbones, equipment-room links, campus connections and general communications infrastructure.

However, rack height alone should not determine product selection. The installer must also consider:

  • Required fibre count
  • Connector and adaptor type
  • Number of fusion splices
  • Incoming cable construction
  • Internal fibre storage requirements
  • Cable entry and routing
  • Patch lead management
  • Future expansion
  • Available rack depth
  • Access for maintenance

Therefore, Anderson Corporation recommends confirming the complete termination design before ordering the enclosure and its associated components.

Unloaded Fibre Enclosure Configuration

The RapidConnect 148S is an unloaded fibre enclosure. In other words, it provides the enclosure platform and internal fibre management hardware without locking the customer into one adaptor and pigtail configuration.

This flexibility allows the customer to select components that match the network. For example, a singlemode installation may require blue SC UPC or LC UPC adaptors. Alternatively, an APC system may require green SC APC or LC APC components. Multimode installations can also use the appropriate multimode adaptors and pigtails.

Because the enclosure is unloaded, customers can determine:

  • Connector format
  • UPC or APC connection type
  • Singlemode or multimode fibre
  • Adaptor quantity
  • Faceplate arrangement
  • Pigtail quantity
  • Fibre count
  • Splice configuration
  • Unused port allowance
  • Future expansion capacity

This approach gives consultants, contractors and network owners greater control over the finished assembly. Furthermore, it prevents the project from paying for pre-installed components that do not match the required design.

Nevertheless, an unloaded enclosure requires careful component selection. The faceplate, adaptors, pigtails and splice accessories must work together as one system. Therefore, Anderson Corporation can help confirm the correct configuration before supply.

Customers who prefer a prepared assembly can also consider the RapidConnect Fully Loaded Rackmount Enclosure.

Maximum 72-Fibre Splice Capacity

The 148S provides a maximum stated splice capacity of up to 72 fibres. However, this figure describes the enclosure’s maximum splice capability when it uses a suitable internal arrangement.

It does not mean that every faceplate and adaptor combination automatically presents 72 fibres. Instead, the usable capacity depends on several connected decisions.

These decisions include:

  • Number of adaptor positions
  • Adaptor format
  • Number of fibres per adaptor
  • Number and arrangement of splice protectors
  • Pigtail routing
  • Incoming cable construction
  • Required service loops
  • Fibre bend-radius requirements
  • Space reserved for future additions

For example, an LC Quad adaptor presents four fibres through one adaptor position. In contrast, an SC Simplex adaptor presents one fibre. Therefore, two faceplates with the same number of physical openings may provide different fibre capacities.

Similarly, a project may not need to use the full splice capacity. A lower-fibre-count installation can retain internal space for easier routing and future expansion. Consequently, the best configuration is not always the highest-density configuration.

Before ordering, customers should confirm both the required splice count and the required number of front-panel connections. Anderson Corporation can then match the faceplates, adaptors and pigtails to the application.

Dual Splice Cassette Design

The RapidConnect 148S incorporates dual splice cassettes for organising and protecting fusion splices. Each cassette provides a controlled location for splice protectors and fibre routing.

After fusion splicing, the technician places each splice protector into the appropriate holder. The technician then routes the fibre within the cassette while maintaining suitable bend control. As a result, the completed splices remain separated from loose cables and other internal components.

Dual cassettes also allow the installer to divide fibres into logical groups. For example, the installer may separate fibres by cable, service, destination, building or network function. Therefore, technicians can identify individual circuits more easily during testing or maintenance.

The dual-cassette arrangement can support:

  • Structured splice storage
  • Separation of fibre groups
  • Controlled fibre routing
  • Protection of fusion splices
  • Clearer identification
  • More efficient maintenance
  • Higher splice density within 1RU

However, high capacity still requires disciplined installation. Technicians should avoid crossing fibres unnecessarily or forcing excess fibre into restricted areas. Furthermore, labels and connection records should match the physical cassette arrangement.

Fibre Bend-Radius Management

Optical fibre can suffer increased attenuation or permanent damage when installers bend it too tightly. Therefore, bend-radius management remains essential throughout the enclosure.

The 148S provides an internal platform for routing fibres around the splice cassettes and towards the front adaptors. When technicians route the fibres correctly, this arrangement helps prevent sharp turns, localised pressure and uncontrolled movement.

Good fibre management should include:

  • Smooth routing paths
  • Suitable service loops
  • Controlled entry into splice cassettes
  • Separation from sharp edges
  • Appropriate support for pigtails
  • Clear routing towards front adaptors
  • Enough movement for the sliding tray
  • No compression beneath enclosure covers

Additionally, installers should follow the minimum bend-radius requirements for the specific cable, pigtail and fibre type. Although the enclosure supports organised routing, installation technique ultimately determines whether the fibres remain properly protected.

Faceplate and Adaptor Options

The 148S can accept different connector faceplates. Therefore, customers can configure the front of the enclosure around their preferred connector system.

Available connector styles include:

  • SC Simplex
  • SC APC Simplex
  • SC Duplex
  • SC APC Duplex
  • LC Duplex
  • LC APC Duplex
  • LC Quad
  • LC APC Quad

The selected faceplate determines the adaptor format and the number of available adaptor positions. Meanwhile, the selected adaptor determines how many fibres each position presents.

SC connectors provide a larger push-pull interface that remains widely used across telecommunications, commercial and industrial networks. LC connectors, however, use a smaller form factor. Consequently, LC configurations can support greater connection density within the available panel space.

UPC and APC connectors must also remain separate. A blue UPC connector should connect to the corresponding UPC adaptor and mating connector. Likewise, a green APC connector should connect only to a compatible APC interface.

Therefore, customers should never select adaptors by colour alone. They should confirm:

  • Connector family
  • Connector polish
  • Fibre mode
  • Adaptor capacity
  • Faceplate compatibility
  • Required fibre count

Correct component selection protects optical performance and prevents mismatched connections.

SC Simplex and SC Duplex Configurations

SC connectors remain common across many fibre optic networks because they provide a familiar push-pull format and a robust connection.

An SC Simplex adaptor supports one fibre connection. Therefore, it suits individual transmit or receive paths and other simplex applications.

In comparison, an SC Duplex arrangement combines two SC connections. Consequently, it can support a conventional two-fibre transmit-and-receive circuit while keeping the paired connections together.

SC configurations may suit:

  • Building backbone links
  • Telecommunications systems
  • Industrial communications
  • Security networks
  • Campus fibre links
  • Equipment-room interconnections
  • Existing networks standardised on SC

However, SC connectors require more front-panel space than LC connectors. Therefore, customers seeking higher density may prefer an LC configuration.

LC Duplex and LC Quad Configurations

LC connectors use a small-form-factor interface. As a result, they can present more fibres within a limited faceplate area.

An LC Duplex adaptor presents two fibres. Therefore, it commonly supports a duplex optical circuit through one compact adaptor body.

An LC Quad adaptor presents four fibres. Consequently, it increases front-panel density and may suit higher-fibre-count installations.

LC configurations may support:

  • High-density communications racks
  • Data networks
  • Equipment interconnection
  • Building backbones
  • Fibre distribution
  • Singlemode and multimode services
  • Networks using LC transceiver interfaces

Nevertheless, the project team should not select LC Quad adaptors based only on maximum density. Internal pigtail routing, splice capacity and patch lead access must also remain manageable. Therefore, the complete enclosure layout should guide the final decision.

UPC and APC Connector Compatibility

The 148S can support both UPC and APC connector formats when fitted with the corresponding faceplates, adaptors and pigtails.

UPC connectors use an ultra-physical-contact polish. They commonly appear in blue for singlemode applications. APC connectors, on the other hand, use an angled physical-contact polish and commonly appear in green.

Because the end-face geometries differ, UPC and APC connectors should not mate with each other. A mismatched connection can produce poor physical contact, excessive insertion loss and unwanted reflectance. Moreover, it may damage the connector end faces.

Therefore, the entire connection path should use a consistent polish type. This includes:

  • Pigtail connector
  • Front adaptor
  • Fibre patch lead
  • Connected equipment or distribution point

Before ordering the unloaded 148S, customers should confirm whether the network uses UPC or APC connectivity.

Singlemode and Multimode Applications

The enclosure does not determine the optical fibre mode. Instead, the installed adaptors, pigtails, patch leads and incoming cable establish the required optical system.

Therefore, the 148S can support singlemode or multimode installations when configured with compatible components.

Singlemode fibre commonly supports longer transmission distances and telecommunications applications. In contrast, multimode fibre often supports shorter links within buildings, data centres and equipment environments.

Regardless of fibre mode, the installer must maintain consistency throughout the channel. For example, an OS2 singlemode cable should connect through compatible singlemode pigtails and patch leads. Likewise, an OM4 multimode cable should use the corresponding OM4 connectivity.

A correctly specified enclosure configuration should confirm:

  • Fibre mode
  • Connector type
  • Connector polish
  • Pigtail specification
  • Adaptor type
  • Patch lead specification
  • Fibre count
  • Network transmission requirements

Consequently, customers should treat the enclosure and its connectivity as one coordinated system.

Fusion-Spliced Fibre Termination

Fusion splicing provides a permanent optical connection between the incoming cable fibres and connectorised pigtails. Therefore, it remains a common termination method for rackmounted fibre enclosures.

A typical installation process includes:

  1. Mount the 148S in the selected rack position.
  2. Prepare and secure the incoming fibre cable.
  3. Route the cable elements into the enclosure.
  4. Prepare the individual fibres for splicing.
  5. Fusion-splice each fibre to its corresponding pigtail.
  6. Protect each completed splice.
  7. Place the splice protectors into the cassette.
  8. Route the remaining fibre within the cassette.
  9. Connect the pigtails to the front-panel adaptors.
  10. Label, inspect and test every completed circuit.
  11. Record the final fibre allocation.

Because fibre preparation and splicing require specialised equipment, trained technicians should complete the work. Furthermore, technicians should inspect and clean every connector before final testing.

Pre-Terminated Fibre Applications

The 148S can also form part of a pre-terminated fibre installation when the selected cable assembly and enclosure configuration allow suitable entry, routing and connection.

Pre-terminated fibre arrives with factory-installed connectors. Therefore, it can reduce field-splicing requirements and shorten installation time. However, the installer must protect the connectors during cable placement and provide sufficient space for routing the terminated ends.

Before using a pre-terminated assembly with the 148S, confirm:

  • Connector type
  • Connector quantity
  • Pulling-eye dimensions
  • Cable entry requirements
  • Internal fan-out length
  • Adaptor arrangement
  • Fibre routing space
  • Bend-radius requirements
  • Patch lead presentation
  • Testing documentation

Accordingly, pre-terminated installations require planning before the cable reaches the site. Anderson Corporation can help coordinate the cable assembly and enclosure configuration.

Cable Entry, Retention and Internal Routing

Incoming cable requires secure retention before technicians route individual fibres towards the splice area. Otherwise, movement or pulling force may transfer to the fibre splices and pigtails.

Therefore, the installer should secure the cable according to its construction and the project design. The cable should enter the enclosure without sharp bends, uncontrolled tension or pressure against other components.

After securing the cable, the installer should route the fibres so that the sliding tray can operate without pulling them. Additionally, the technician should allow controlled movement where the cable transitions between fixed and sliding sections.

A well-managed installation should provide:

  • Stable cable entry
  • Effective strain control
  • Clear separation of cable and fibre elements
  • Smooth routing into the splice cassettes
  • Controlled movement during tray operation
  • Accessible identification labels
  • Protection from sharp surfaces
  • Space for inspection and maintenance

The correct method will depend on the incoming cable construction. Therefore, installers should review the cable specification before beginning termination work.

Connection Records and Fibre Identification

The RapidConnect 148S includes a connection record book to help document installed fibre circuits.

Accurate records allow technicians to identify each adaptor, pigtail, splice and incoming fibre. Consequently, they can trace circuits more quickly during testing, fault investigation or network changes.

At a minimum, the records should identify:

  • Cable name or number
  • Fibre number
  • Fibre colour
  • Splice cassette position
  • Adaptor port
  • Destination
  • Service or circuit
  • Test result
  • Installation date
  • Technician or contractor

Additionally, front-panel labels should correspond with the internal records. Consistent identification reduces uncertainty and helps prevent technicians from disconnecting the wrong service.

However, documentation only remains useful when teams keep it current. Therefore, every move, addition or change should include an update to the connection record.

Suitable Installation Environments

The 148S suits protected indoor rack and cabinet installations. Depending on the complete network design, it may form part of:

  • Commercial building networks
  • Communications rooms
  • Main distribution frames
  • Intermediate distribution frames
  • Data and equipment cabinets
  • Campus backbone systems
  • Industrial communications rooms
  • Security and surveillance networks
  • Telecommunications installations
  • Structured cabling systems

However, the standard enclosure does not provide an outdoor weatherproof housing. Therefore, customers should install it within a suitable indoor rack, cabinet or protected equipment environment.

The surrounding cabinet should also provide enough depth and clearance for the enclosure, incoming cable and patch leads. Moreover, technicians should retain clear access to the sliding tray.

Unloaded Versus Fully Loaded Enclosures

The unloaded and fully loaded versions serve different project requirements.

An unloaded enclosure gives the customer maximum control over the final configuration. Therefore, it suits projects with specialised connector requirements, unusual fibre counts or staged deployment plans.

A fully loaded enclosure includes selected connectivity components before delivery. Consequently, it can reduce component selection and site preparation.

Consideration Unloaded 148S Fully loaded enclosure
Faceplates Selected separately Configured before supply
Adaptors Selected separately Pre-installed as ordered
Pigtails Selected separately Supplied as part of configuration
Configuration flexibility Maximum Defined before delivery
Site preparation More component assembly Reduced component assembly
Best suited to Custom or staged configurations Standardised, prepared installations

Neither approach is universally better. Instead, the correct choice depends on the project design, labour model and required level of factory preparation.

For a prepared solution, view the RapidConnect Fully Loaded Rackmount Enclosure.

Installation Planning

Careful planning helps installers use the available enclosure space effectively. Therefore, the project team should confirm the full design before equipment arrives on site.

The planning process should include:

Confirm the required fibre count

First, identify the number of fibres that require immediate termination. Then, consider future expansion and spare capacity.

Select the connector format

Next, choose SC or LC connectivity. The choice should match the existing network, equipment interfaces and required panel density.

Confirm UPC or APC

The connector polish must remain consistent throughout the optical path. Therefore, confirm UPC or APC before selecting adaptors and pigtails.

Select the faceplate

The faceplate must match the adaptor format and required port count. Additionally, it must support practical patch lead access.

Plan the splice arrangement

Determine how many fusion splices the enclosure will hold. Then, assign fibres across the dual splice cassettes.

Confirm cable entry

Review the incoming cable diameter, construction and bend radius. Furthermore, plan how the installer will secure and route the cable.

Allow for maintenance

Finally, confirm that the rack position gives technicians enough clearance to open the sliding tray and access the patching area.

This process reduces ordering errors and supports a cleaner installation.

Inspection, Cleaning and Testing

Contaminated fibre connectors can cause insertion loss, reflectance and unstable network performance. Therefore, technicians should inspect and clean every connector before mating it.

A suitable process includes:

  1. Inspect the connector end face.
  2. Clean it with an approved fibre cleaning method when necessary.
  3. Inspect it again.
  4. Connect it only after confirming cleanliness.
  5. Test the completed optical path.
  6. Record the result.

Additionally, technicians should keep unused adaptor ports protected with dust caps. However, a dust cap does not guarantee that an interface is clean. Therefore, technicians should still inspect the connection before use.

After termination, the installer should complete the required optical testing. Therefore, depending on the project, this may include insertion-loss testing, polarity confirmation and OTDR testing.

The results should then become part of the project handover documentation.

Maintenance and Network Changes

The sliding tray simplifies access, but technicians must still follow a controlled maintenance process.

Before opening the enclosure, identify the affected circuit and review the connection records. Next, check that patch leads and incoming cables have enough controlled movement. Then, slide the tray forward without applying force to the fibres.

During maintenance:

  • Avoid disturbing unrelated circuits
  • Keep patch leads identified
  • Maintain fibre bend radius
  • Inspect connectors before reconnection
  • Replace dust caps on unused ports
  • Update labels and records
  • Retest changed circuits
  • Return the tray carefully to its operating position

Consequently, the enclosure can support future additions and changes without turning the fibre termination area into an unmanaged collection of fibres and patch leads.

Technical Specifications – 1RU Rackmount Sliding Fibre Enclosure

Specification Details
Product RapidConnect 1RU Rackmount Sliding Fibre Enclosure
Product code 148S
Configuration Unloaded
Rack height 1RU
Enclosure type Rackmount sliding fibre enclosure
Maximum stated splice capacity Up to 72 fibres
Splice management Dual splice cassettes
Connector options SC, SC APC, LC and LC APC
Adaptor formats SC Simplex, SC Duplex, LC Duplex and LC Quad
Unpacked dimensions 430 × 300 × 44 mm
Unpacked weight 3.12 kg
Packaged dimensions 510 × 370 × 70 mm
Packaged weight 5 kg
Connection record Included
Application Protected indoor rack and cabinet installations

Because each project can use a different faceplate and adaptor arrangement, customers should confirm the required configuration before ordering.

Download the 148S Unloaded Sliding Enclosure Brochure

Associated Fibre Components

A complete 148S configuration may require:

  • Fibre adaptor faceplates
  • SC or LC adaptors
  • UPC or APC adaptors
  • Singlemode or multimode pigtails
  • Splice protectors
  • Fibre identification labels
  • Fibre patch leads
  • Connector cleaning products
  • Fusion-splicing equipment
  • Optical test equipment
  • Incoming fibre optic cable

However, component requirements vary between projects. Therefore, customers should provide the fibre count, fibre mode, connector type and preferred configuration when requesting a quotation.

Why Choose the RapidConnect 148S 1RU Rackmount Sliding Fibre Enclosure?

The RapidConnect 148S provides a practical balance between rack-space efficiency, configuration flexibility and technician access.

Key advantages include:

  • Compact 1RU format
  • Sliding access to internal fibres
  • Up to 72-fibre splice capacity
  • Dual internal splice cassettes
  • Unloaded configuration flexibility
  • Multiple SC and LC adaptor options
  • UPC and APC compatibility
  • Support for singlemode and multimode systems
  • Organised fibre and splice management
  • Connection record book
  • Compatibility with RapidConnect fibre components
  • Support from Anderson Corporation

Moreover, Anderson Corporation can help customers select the faceplates, adaptors, pigtails and other components required for the finished enclosure.

RapidConnect 25-Year System Warranty

The RapidConnect 148S can form part of the RapidConnect 25-Year Enterprise Cabling Infrastructure System Warranty when the complete installation meets the applicable warranty conditions.

A system warranty considers the installed cabling channel rather than one individual component. Therefore, the project must use approved products, installation practices and testing procedures.

Customers should discuss warranty requirements with Anderson Corporation during the project design stage. That way, the correct products and documentation can be incorporated before installation begins.

Frequently Asked Questions – 1RU Rackmount Sliding Fibre Enclosure

Is the RapidConnect 148S a 1RU enclosure?

Yes. The enclosure has an unpacked height of 44 mm and occupies one rack unit within a compatible rack or cabinet.

What does “unloaded” mean?

Unloaded means the enclosure does not force the customer into one preselected adaptor and pigtail configuration. Instead, customers select the appropriate faceplates, adaptors and pigtails for their network.

How many fibres can the 148S hold?

The enclosure provides a maximum stated splice capacity of up to 72 fibres. However, the number of fibres presented at the front panel depends on the selected faceplate and adaptor arrangement.

Does every configuration support 72 front-panel connections?

No. The final front-panel capacity depends on the number of adaptor positions and whether the enclosure uses SC Simplex, SC Duplex, LC Duplex or LC Quad adaptors.

Which connector types can the enclosure support?

The available options include SC Simplex, SC APC Simplex, SC Duplex, SC APC Duplex, LC Duplex, LC APC Duplex, LC Quad and LC APC Quad.

Can the enclosure support LC Quad adaptors?

Yes. LC Quad and LC APC Quad options are available. Each quad adaptor presents four fibres, subject to the selected faceplate and complete enclosure configuration.

Can the 148S support both UPC and APC connections?

Yes. However, the faceplate, adaptors, pigtails and patch leads must use the correct and matching connector polish. UPC and APC connectors should not mate with each other.

Can it support singlemode and multimode fibre?

Yes. The enclosure can support either fibre mode when fitted with compatible adaptors, pigtails and patch leads.

Does the enclosure include splice cassettes?

Yes. The 148S includes dual splice cassettes for organising and protecting fibre splices.

Why does the enclosure use a sliding tray?

The sliding tray gives technicians easier access to internal fibres, splices and connections. Consequently, installation, inspection and maintenance can take place while the enclosure remains mounted in the rack.

Can I use the 148S for pre-terminated fibre?

The enclosure can form part of a pre-terminated solution when the cable assembly, cable entry and internal routing suit the selected configuration. Therefore, confirm the complete design before ordering.

Is a fully loaded version available?

Yes. Customers who want adaptors and pigtails configured before delivery can consider the RapidConnect Fully Loaded Rackmount Enclosure.

What are the enclosure dimensions?

Without packaging, the enclosure measures 430 × 300 × 44 mm. With packaging, it measures 510 × 370 × 70 mm.

How much does the enclosure weigh?

The unpacked enclosure weighs 3.12 kg. Meanwhile, its packaged weight is 5 kg.

Does the enclosure include a connection record?

Yes. A connection record book is supplied to help document fibre allocations and installed circuits.

Is the 148S suitable for outdoor installation?

The standard 148S suits protected indoor racks and cabinets. Therefore, it should not be treated as a weatherproof outdoor enclosure.

How do I select the correct configuration?

Provide Anderson Corporation with the required fibre count, fibre mode, connector type, connector polish and preferred adaptor arrangement. Therefore, the team can then help identify the appropriate faceplates, adaptors and pigtails.

1RU Rackmount Sliding Fibre Enclosure Knowledge Centre

The 1RU Rackmount Sliding Fibre Enclosure Knowledge Centre provides focused guidance across enclosure selection, fibre capacity, connector configurations, installation and maintenance. As the Knowledge Centre expands, each section will help customers plan and manage rackmounted fibre terminations throughout the complete product lifecycle.

Rackmount Fibre Enclosure Fundamentals

First, this section explains how rackmount fibre enclosures protect, terminate and organise optical fibres within communications racks and cabinets.

Articles coming soon.

Fibre Capacity and Enclosure Configuration

Next, this section explores splice capacity, presented-fibre capacity, adaptor density and future expansion. In particular, it will explain why final capacity depends on the complete enclosure configuration.

Articles coming soon.

Adaptors, Pigtails and Faceplates

This section explains how faceplates, adaptors and pigtails work together. Additionally, it will cover SC, LC, UPC and APC selection.

Articles coming soon.

Installation and Cable Management

Here, installers can learn about rack mounting, cable entry, strain control, internal fibre routing and bend-radius management.

Articles coming soon.

Fusion Splicing and Pre-Terminated Fibre

This section compares fusion-spliced termination with pre-terminated deployment. Furthermore, it will explore how each method affects project planning and installation.

Articles coming soon.

Inspection, Testing and Maintenance

Finally, this section covers connector inspection, cleaning, optical testing, labelling, record keeping and ongoing enclosure maintenance.

Articles coming soon.

Configure Your 1RU Rackmount Sliding Fibre Enclosure

The RapidConnect 148S offers a flexible foundation for rackmounted fibre termination. Because it is supplied unloaded, customers can select the faceplates, adaptors and pigtails that match their precise network requirements.

Furthermore, its sliding tray provides direct access to the internal fibre management area. The dual splice cassettes then help organise and protect up to 72 fusion splices within a compact 1RU format.

Contact Anderson Corporation to confirm your fibre count, connector style, adaptor arrangement and pigtail requirements. Alternatively, use the Rapid Quote form to request a configured solution.

Request a Quote

For more fibre optic product guidance, visit the Anderson Fibre Products YouTube Channel.

 