100G QSFP28 Transceiver

The Yamasaki 100G QSFP28 Transceiver range supports high-capacity fibre connections for data centres, enterprise networks and telecommunications. Choose from SR4, CWDM4, PSM4, LR4, receive-only LR4, ER4 Lite and ER4 configurations, with nominal reaches up to 40km. Options include multimode or singlemode fibre and MPO, duplex LC or simplex LC interfaces, depending on the model.

Attachments

File File size
100G SFP Series 859 KB

100G QSFP28 Transceiver

The Yamasaki 100G QSFP28 Transceiver range provides high-capacity optical connectivity for data centres, enterprise backbones, campus networks and telecommunications infrastructure. With multimode and singlemode configurations, the range supports short connections up to 100 metres and longer links up to 40 kilometres, depending on the selected module and channel conditions.

Furthermore, the range includes SR4, CWDM4, PSM4, LR4, receive-only LR4, ER4 Lite and ER4 configurations. As a result, network designers can select an optical interface that matches the available fibre, required distance and host equipment.

However, choosing a transceiver requires more than matching speed and distance. Connector architecture, optical wavelengths, channel loss and equipment compatibility also influence reliable operation.

For assistance selecting the appropriate Yamasaki module, request a Rapid Quote. Include your equipment model, fibre details, required distance and remote-end optic so Anderson Corporation can review the complete application.

What Is a 100G QSFP28 Transceiver?

A 100G QSFP28 Transceiver connects compatible network equipment to optical fibre. It converts electrical signals from the host into optical signals for transmission and converts incoming optical signals back into electrical signals.

Typically, QSFP28 supports 100 Gigabit Ethernet through four electrical lanes operating at approximately 25 Gbit/s each. However, the optical arrangement depends on the selected module.

For example, SR4 uses parallel multimode optical paths. In contrast, LR4 combines several optical wavelengths over a duplex singlemode fibre pair.

Consequently, two modules can share the QSFP28 form factor while requiring different cables and optical interfaces. Therefore, always identify the complete module configuration before selecting associated connectivity.

For further background, read SFP vs SFP+ vs QSFP: What Is the Difference?.

Yamasaki 100G QSFP28 Transceiver Range

The Yamasaki range includes nine configurations covering different optical architectures and listed data-rate capabilities.

Yamasaki configuration Listed data rate Optical wavelength Fibre type Connector Nominal maximum reach
SR4, 112 Gbit/s variant 112 Gbit/s 850 nm Multimode MPO 100 m
SR4, 103.1 Gbit/s variant 103.1 Gbit/s 850 nm Multimode MPO 100 m
CWDM4 103.1–112 Gbit/s CWDM, 1271–1331 nm Singlemode Duplex LC 2 km
PSM4, 2 km variant 103.1–112 Gbit/s 1310 nm Singlemode MPO 2 km
LR4, wider-rate variant 103.1–112 Gbit/s LAN-WDM, approximately 1294–1310 nm Singlemode Duplex LC 10 km
LR4, 103.1 Gbit/s variant 103.1 Gbit/s LAN-WDM, approximately 1294–1310 nm Singlemode Duplex LC 10 km
LR4 receive-only 103.1–112 Gbit/s LR4 receive interface Singlemode Simplex LC 10 km reference application
ER4 Lite 103.1–112 Gbit/s LAN-WDM, approximately 1294–1310 nm Singlemode Duplex LC 30 km
ER4 103.1–112 Gbit/s LAN-WDM, approximately 1294–1310 nm Singlemode Duplex LC 40 km

These reach figures provide a starting point for selection. However, actual operation depends on the complete optical channel, receiver limits, host configuration and applicable forward error correction requirements.

Similarly, a listed data-rate range does not establish support for every protocol at those rates. Therefore, confirm the exact application before ordering.

SR4 Multimode Modules for Short Connections

Yamasaki SR4 modules provide parallel multimode connectivity for short optical links. Typically, these connections serve equipment rooms, data centre switches and other installations with suitable multimode infrastructure.

The range includes two SR4 variants. Although both use 850 nm optics and MPO connectivity, their listed data-rate capabilities differ.

SR4: 103.1 Gbit/s variant

This configuration specifies a 103.1 Gbit/s aggregate data rate and a nominal maximum reach of 100 metres over suitable multimode fibre.

For example, it may suit a short 100G connection between compatible switches where the complete channel meets the module requirements. However, the fibre category and channel loss still require verification.

Therefore, record the installed multimode fibre type, total length and number of intermediate connections before selecting the module.

SR4: 112 Gbit/s variant

The second SR4 configuration specifies a 112 Gbit/s data rate. Like the 103.1 Gbit/s version, it uses an MPO interface and lists a maximum reach of 100 metres over suitable multimode fibre.

However, the higher listed rate does not automatically make it suitable for every 100G application. Instead, match the module to the host operating mode and required protocol.

Additionally, confirm the remote-end module and any relevant equipment configuration requirements.

Multimode fibre and polarity

Common 100GBASE-SR4 implementations support different distances over OM3 and OM4 fibre. Therefore, do not treat the 100 metre rating as applicable to every multimode channel.

Furthermore, SR4 relies on correctly mapped parallel optical paths. An incorrect polarity arrangement can prevent communication even when the fibre length and module type appear suitable.

Consequently, assess the full channel, including trunks, patch leads, adaptors and intermediate connections.

CWDM4 Modules for Duplex Singlemode Links

The Yamasaki CWDM4 module provides a nominal reach of up to 2 kilometres over singlemode fibre. It specifies duplex LC connectivity, CWDM wavelengths across 1271–1331 nm and a listed data-rate range of 103.1–112 Gbit/s.

Within this architecture, the module combines four optical wavelengths onto one transmit fibre. Meanwhile, the second fibre carries traffic in the opposite direction.

As a result, CWDM4 supports an aggregate optical connection over a duplex fibre pair. This arrangement can suit installations that already provide suitable singlemode LC infrastructure.

However, a duplex LC connector does not establish compatibility with other LC-based optics. For example, CWDM4 and LR4 use different wavelength arrangements.

Therefore, match the optical interface at both ends of the link. In addition, confirm the host equipment, operating rate and applicable FEC requirements.

PSM4 Modules for Parallel Singlemode Connections

The Yamasaki PSM4 configuration uses parallel singlemode optics at 1310 nm. This particular variant specifies a nominal maximum reach of 2 kilometres, an MPO interface and a listed data-rate range of 103.1–112 Gbit/s.

Although PSM4 and CWDM4 both offer 2 kilometre options within the range, their cabling requirements differ.

CWDM4 combines wavelengths over a duplex pair. In contrast, PSM4 carries its optical lanes across separate singlemode fibre paths.

Consequently, PSM4 selection should consider the available fibre count and existing patching architecture. Distance alone cannot determine which option suits the installation.

Furthermore, confirm the MPO connector polish, pinning, fibre mapping and polarity before ordering associated assemblies. Every component must preserve the required optical paths.

For related connectivity, explore the RapidConnect MPO Trunk Cable range. Specify the transceiver requirements first so the cable assembly matches the complete optical interface.

LR4 Modules for 10 Kilometre Connections

The Yamasaki LR4 range includes two full transmit-and-receive configurations. Both specify duplex LC connectivity, singlemode fibre and a nominal maximum reach of 10 kilometres.

Additionally, both use LAN-WDM optical wavelengths within approximately 1294–1310 nm. However, their listed data-rate capabilities differ.

LR4: 103.1 Gbit/s variant

The 103.1 Gbit/s version provides an LR4 option for compatible 100G applications. It uses a duplex singlemode fibre pair to carry traffic between the connected endpoints.

For procurement, identify the required operating mode and exact host equipment. Then, confirm that the remote-end optic provides the corresponding LR4 interface.

Additionally, include the existing module details when requesting a replacement. This helps distinguish the required version from the wider-rate alternative.

LR4: 103.1–112 Gbit/s variant

The wider-rate LR4 configuration specifies operation across 103.1–112 Gbit/s. It retains the duplex LC interface and nominal 10 kilometre singlemode reach.

However, the broader rate specification does not establish universal protocol support. Therefore, confirm the intended application and host operating requirements before selecting this version.

Likewise, check the remote-end module rather than assuming that every LR4-labelled product supports the same operating modes.

Assessing an LR4 channel

A route shorter than 10 kilometres can still exceed the module’s allowable loss. For example, numerous patching points, contaminated connectors or damaged fibre can reduce the available optical margin.

Therefore, use measured insertion loss wherever possible. In addition, account for planned patch panels and future maintenance connections when assessing the channel.

LR4 Receive-Only Module

The Yamasaki range also includes a receive-only LR4 configuration. It specifies a simplex LC interface, singlemode fibre and a listed data-rate range of 103.1–112 Gbit/s.

Unlike a conventional transceiver, this module receives incoming optical signals without providing return optical transmission. Consequently, it serves a different purpose from a normal bidirectional LR4 module.

It may suit compatible monitoring or capture equipment that explicitly supports receive-only operation. However, the platform must accept the module and process the incoming signal correctly.

The listed 10 kilometre reference also requires careful interpretation. Because the module receives only, the source transmitter and complete optical path determine the available receive power.

For example, a monitoring tap introduces additional loss that must form part of the assessment. Therefore, provide the tap ratio, source optic and channel details with your enquiry.

Finally, state receive-only LR4 clearly on the purchase order. A general request for “100G LR4, 10 km” does not adequately identify this configuration.

ER4 Lite Modules for 30 Kilometre Links

The Yamasaki ER4 Lite module provides a nominal maximum reach of 30 kilometres over suitable singlemode fibre.

This configuration specifies duplex LC connectivity, LAN-WDM wavelengths and a listed data-rate range of 103.1–112 Gbit/s. As a result, it provides an option for routes that extend beyond the LR4 reach category.

However, the ER4 Lite designation does not define every operating condition. Therefore, confirm the exact optical budget, receiver limits and host FEC requirements for the supplied module.

Additionally, assess the actual channel loss rather than relying entirely on route length. Splices, connectors and intermediate patching all contribute to the optical path.

Where possible, provide test results with the enquiry. This information supports a more accurate assessment of the proposed connection.

ER4 Modules for 40 Kilometre Links

The Yamasaki ER4 configuration provides the longest listed reach within this range: up to 40 kilometres over suitable singlemode fibre.

It specifies duplex LC connectivity, LAN-WDM optics and a data-rate range of 103.1–112 Gbit/s. Therefore, it provides an extended-reach option for appropriately engineered links.

However, longer-distance selection requires more than sufficient transmitter power. The complete design must keep received power within the receiver’s permitted operating range.

Consequently, assess both minimum and maximum receive levels. On shorter or particularly low-loss paths, the design may require optical attenuation.

Furthermore, confirm the relevant host FEC settings and the conditions attached to the module’s reach rating. These checks help establish whether the selected configuration suits the actual route.

How to Select a 100G QSFP28 Transceiver

A structured selection process helps align the host equipment, optical interface and fibre channel.

1. Confirm the host equipment

First, identify the switch, router, line card or monitoring platform. Record the manufacturer, exact model and operating software.

Then, confirm that the selected port supports the required QSFP28 operating mode. Physical fit alone does not establish electrical or firmware compatibility.

2. Define the application

Next, determine whether the connection requires a conventional bidirectional link, a supported breakout arrangement or receive-only monitoring.

Additionally, identify the required protocol and operating data rate. This distinction matters when choosing between standard-rate and wider-rate variants.

3. Identify the fibre infrastructure

Check the fibre category, available strand count and installed connectors.

For example, an existing duplex LC singlemode channel presents different options from a parallel MPO channel. Therefore, inspect the infrastructure before choosing the optical architecture.

4. Match the optical interface

Select SR4, CWDM4, PSM4, LR4, receive-only LR4, ER4 Lite or ER4 according to the application.

However, avoid selecting by connector alone. Both SR4 and PSM4 use MPO, while several different wavelength-based interfaces use duplex LC.

5. Assess distance and loss

Record the complete route length and measured insertion loss. Include connectors, splices, patch panels and any passive monitoring devices.

Then, compare the channel against the selected module’s optical limits. Additionally, allow an appropriate engineering margin for the application.

6. Verify the remote endpoint

Finally, identify the optic and equipment at the opposite end.

Confirm the optical interface, operating rate and configuration requirements. Likewise, check any relevant FEC settings before placing the order.

Cabling for a 100G QSFP28 Transceiver

The cable assembly forms part of the optical system. Therefore, its fibre type, connector arrangement and loss characteristics must match the selected module.

MPO connectivity

For SR4 and PSM4 installations, specify:

  • Multimode or singlemode fibre.
  • Required fibre count and lane mapping.
  • Connector polish.
  • Male or female connector arrangement.
  • End-to-end polarity.
  • Maximum permitted channel loss.

Furthermore, assess the entire path through trunks and patching components. A correctly specified patch lead cannot resolve incorrect fibre mapping elsewhere in the channel.

Duplex LC connectivity

CWDM4, full LR4, ER4 Lite and ER4 configurations use duplex LC connectivity within this range.

However, the shared connector does not make these optical interfaces interchangeable. Therefore, match the module type and wavelengths as well as the connector.

Additionally, confirm transmit-to-receive orientation and the required connector polish throughout the path.

Simplex LC receive-only connectivity

The receive-only LR4 module uses a simplex LC incoming optical connection.

Consequently, the design must identify the source signal and any intervening tap or splitter. This allows the receive power and monitoring arrangement to be assessed together.

Compatibility and Operating Requirements

Equipment compatibility

A 100G QSFP28 Transceiver must match the host’s electrical interface, supported operating mode and module acceptance requirements.

Therefore, provide the exact equipment model and software version with the enquiry. For replacement work, also include the existing module label and port configuration.

Breakout operation

Some applications divide a supported 100G interface into four independent 25G connections. However, this requires suitable host support, optical architecture, remote interfaces and cabling.

Consequently, do not assume that every QSFP28 module supports breakout. Describe the intended arrangement explicitly so the complete configuration can be reviewed.

FEC settings

Forward error correction requirements depend on the selected optical interface and host implementation.

Therefore, confirm the required settings at both endpoints. Likewise, check whether the advertised reach relies on a particular FEC mode.

Temperature and airflow

The listed configurations specify a standard operating case-temperature range of 0°C to 70°C, with extended or industrial options subject to confirmation.

However, module case temperature differs from room temperature. Restricted airflow and neighbouring high-power modules can increase operating temperatures.

Therefore, confirm the required temperature grade and host thermal limits before deployment.

Installation and Commissioning

Careful installation helps preserve the performance of the optical channel.

First, verify the module labels against the approved specification. Then, confirm the fibre type, connector arrangement and remote-end interface.

Before mating connectors, inspect and clean them using suitable fibre inspection and cleaning equipment. Furthermore, retain protective caps until the connection is ready.

After installation, check the port status and available diagnostic information. Where supported, review receive power, temperature and relevant error counters.

If the link does not operate correctly, investigate systematically. For example, check host acceptance, speed configuration, FEC, polarity and channel loss before replacing components.

Finally, record the installed modules and test results. This documentation supports future maintenance and replacement decisions.

Procurement and Specification Checklist

A detailed enquiry helps identify the correct configuration and associated connectivity.

Requirement Information to provide
Product Yamasaki 100G QSFP28 Transceiver
Optical configuration SR4, CWDM4, PSM4, LR4, receive-only LR4, ER4 Lite or ER4
Operating requirement Required protocol, data rate and port mode
Host equipment Manufacturer, model, line card and software
Fibre infrastructure Fibre category, specification and available strands
Channel information Route length and measured insertion loss
Connector arrangement MPO, duplex LC or simplex LC, including interface details
Remote endpoint Existing or proposed optic and host equipment
Operating conditions Required temperature grade and installation environment
Delivery requirements Quantity, project timing and spare-module requirements

Additionally, provide a photograph of the existing module label when replacing an installed optic. This can reveal important distinctions that a short product description may overlook.

Frequently Asked Questions

What is the difference between SR4 and LR4?

SR4 uses parallel multimode optics with an MPO interface. In contrast, LR4 uses wavelength-multiplexed singlemode optics with duplex LC connectivity.

Therefore, the two configurations require different fibre arrangements.

Are CWDM4 and PSM4 interchangeable?

They use different optical architectures. Although both offer a listed 2 kilometre reach within this range, CWDM4 uses duplex LC while PSM4 uses parallel singlemode MPO connectivity.

Consequently, changing between them requires assessment of the cabling and both optical endpoints.

Why does the range include two SR4 variants?

The variants have listed data rates of 103.1 Gbit/s and 112 Gbit/s. Therefore, select the version that matches the host operating mode and required application.

Why are there two full LR4 variants?

Both specify a nominal maximum reach of 10 kilometres. However, one lists 103.1 Gbit/s operation, while the other lists 103.1–112 Gbit/s.

Can the receive-only module replace a normal LR4 transceiver?

It cannot provide the return optical transmission required for a conventional bidirectional link. Therefore, use it only with equipment and applications that support receive-only operation.

Does a 40 kilometre rating guarantee operation on every shorter route?

No. The complete channel must meet the module’s optical requirements.

Additionally, very low-loss paths require assessment against the receiver’s maximum permitted input power.

Can I select a module by connector type?

No. Several different optical interfaces share MPO or LC connectors.

Therefore, confirm the fibre, wavelengths, optical architecture and remote-end module as well as the connector.

100G QSFP28 Transceiver Knowledge Centre

Explore the Fibre Talk Knowledge Centre for further guidance on optical interfaces, fibre connectivity and network product selection.

Related resources include:

Additionally, review the selected module’s detailed specification alongside the host equipment documentation before finalising an order.

For practical fibre optic guidance, product demonstrations and educational videos, visit the Anderson Fibre Optic Products YouTube Channel. Additionally, subscribe to keep up with new videos from Anderson Corporation.

Choose the Right Yamasaki 100G QSFP28 Transceiver

The Yamasaki 100G QSFP28 Transceiver range covers short multimode connections, duplex and parallel singlemode links, receive-only applications and extended-distance routes.

However, reliable selection depends on matching the complete system. Start with the host equipment and required optical interface, then assess the fibre, operating rate, connector arrangement and channel loss.

For pricing, availability or technical assistance, request a Rapid Quote. Provide your host equipment details, remote-end optic and fibre channel information so Anderson Corporation can help identify the appropriate Yamasaki configuration.